English
Language : 

760800080 Datasheet, PDF (1/5 Pages) Wurth Elektronik GmbH & Co. KG, Germany. – WE-PFC PFC Choke
A Dimensions: [mm]
B Hole Pattern: [mm]
C Schematic:
D Electrical Properties:
Properties
Inductance
Rated Current
Saturation Current
DC Resistance 1
DC Resistance 2
Input Voltage
Turns Ratio
Output Power 1
Insulation Test Voltage
Test conditions
100 kHz/ 100 mV
∆T = 40 K
|ΔL/L| < 20%
L
IR
Isat
RDC1
RDC2
Ui
n
Po
UT
Value
1800
0.3
1.0
1550
1200
85-265
12.9 : 1
25
1500
Unit
µH
A
A
mΩ
mΩ
V (AC)
W
V (AC)
Tol.
±10%
max.
typ.
max.
max.
±3%
E General information:
It is recommended that the temperature of the part does not exceed 125°C un-
der worst case operating conditions.
Ambient temperature: -40°C to +85°C (refering to IR)
Operating temperature: -40°C to +125°C
Storage temperature (in tray packaging): -20°C to +40°C; 75% RH max.
Test conditions of Electrical Properties: 20°C, 33% RH
if not specified differently
DESCRIPTION
WE-PFC PFC Choke
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Order.- No.
SIZE
1.1
2012-06-28
SSt
1.0
2012-05-01
SSt
SSt
Tel. +49 (0) 79 42 945 - 0
MiBr
www.we-online.com
760800080
A4
eiSos@we-online.com
REV
DATE
BY
CHECKED
Size: EE20/10/6
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use.
Moreover Würth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before