English
Language : 

760308101220 Datasheet, PDF (1/6 Pages) Wurth Elektronik GmbH & Co. KG, Germany. – WE-WPCC Wireless Power Charging Receiver Coil
Dimensions: [mm]
A
O 17,0 ± 0,3
25,0 ± 2,0
5,0 ± 2,0
Recommended Hole Pattern: [mm]
1
2,0 min.
O 1,0
2
Electrical Properties
Properties
Test conditions
Inductance
125 kHz/ 10 mA
L
Q-factor
125 kHz/ 10 mA
Q
Rated Current
ΔT = 40 K
IR
Saturation Current
ISAT
DC Resistance
@ 20°C
RDC
DC Resistance
@ 20°C
RDC
Self Resonant Frequency
fres
Value
12.6
20
1.1
2.5
0.27
0.34
19
Unit
Tol.
μH
±10%
typ.
A
max.
A
typ.
Ω
typ.
Ω
max.
MHz
detail A
Copper Coil
Glue
PET
Ferrite Sheet
Doublefaced Adhesive Tape
Release Paper
Schematic:
Scale - 1:1,5
General Information
Properties
Value
It is recommeded that the temperature of the component does not exceed +105°C under worst
case conditions
Operating Temperature
Storage Temperature (in original
packaging)
TOP
-20 °C up to +105 °C
TS
-20 °C up to +60 °C
Test conditions of Electrical Properties: 20°C, 33% RH if not specified differently
Scale - 2:1
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CREATED
WE
CHECKED
WE
GENERAL TOLERANCE
DIN ISO 2768-1m
PROJECTION
METHOD
DESCRIPTION
WE-WPCC Wireless Power
Charging Receiver Coil
SIZE
Ø 17
REVISION
001.001
STATUS
Draft
ORDER CODE
760308101220
DATE
BUSINESS UNIT
PAGE
2015-12-01
1/6
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.