English
Language : 

744866563 Datasheet, PDF (1/5 Pages) Wurth Elektronik GmbH & Co. KG, Germany. – WE-FCL Common Mode Power Line Choke
A Dimensions: [mm]
B Recommended hole pattern: [mm]
C Schematic:
D Electrical Properties:
Properties
Test conditions
Inductance
10 kHz/ 0.1 mA
L
Rated current
@ 70°C
IR
DC Resistance
@ 20°C
RDC
Rated voltage
50 Hz
UR
Insulation test voltage
50 Hz
UT
Value
2x 56
1.5
2x 530
250
1500
Unit
mH
A
mΩ
V (AC)
V (AC)
Tol.
±30%
min.
max.
max.
E General information:
It is recommended that the temperature of the part does
not exceed +125°C under worst case conditions.
•Storage Temperature: -20°C to 60°C
•Operating Temperature: -40°C to 125°C
•Temperature Rise: < 55K
•Test conditions of Electrical Properties: 20°C, 33% RH
if not specified differently
DESCRIPTION
WE-FCL Common Mode Power Line Choke
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Order.- No.
SIZE
1.0
2015-03-19
SSt
Tel. +49 (0) 79 42 945 - 0
IMA
www.we-online.com
744866563
A4
eiSos@we-online.com
REV
DATE
BY
CHECKED
Size: ET35
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use.
Moreover Würth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before
the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.