English
Language : 

744839010400 Datasheet, PDF (1/5 Pages) Wurth Elektronik GmbH & Co. KG, Germany. – Insulation Test Voltage
Dimensions: [mm]
2
5
3
64
A1
detail A
1
O 3,9 max.
O 70,0 max.
3x O 1,5 typ.
6,0 min.
Recommended Hole Pattern: [mm]
O 5,0
1
6
3
4
5
2
6x O4,2
Electrical Properties:
Properties
Inductance
Rated Current
DC Resistance
Insulation Test Voltage
Test conditions
10 kHz/ 0.1 mA L
@ 70 °C
IR
@ 20 °C
RDC
50 Hz/ 2 sec.
UT
Value
3x10.5
40
3x3.2
3000
Unit Tol.
mH ±50%
A max.
mΩ max.
V (AC)
Schematic:
1
2
3
General Information:
4
It is recommeded that the temperature of the component does not exceed +125°C under worst
case conditions
65
Storage Temperature (in original
packaging)
-20 °C up to +60 °C
67
Operating Temperature
-40 °C up to +125 °C
Temperature Rise < 55K
Due to heavy weight, we recommend to fix the component on PCB with a self tapping screw:
4.8*xx = screw length, depends from used PCB thickness
Test conditions of Electrical Properties: +20°C, 33% RH if not specified differently
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CREATED
KaS
CHECKED
HasA
GENERAL TOLERANCE
DIN ISO 2768-1m
PROJECTION
METHOD
DESCRIPTION
WE-TPBHV Three-Phase Common
Mode Power Line Choke
ORDER CODE
744839010400
SIZE
4XL
REVISION
001.000
STATUS
Valid
DATE
BUSINESS UNIT
PAGE
2016-09-16
eiSos
1/5
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.