English
Language : 

744762182A Datasheet, PDF (1/5 Pages) Wurth Elektronik GmbH & Co. KG, Germany. – WE-KI SMD Wire Wound Ceramic Inductor
A Dimensions: [mm]
B Recommended land pattern: [mm]
D Electrical Properties:
Properties
Test conditions
Value Unit
Tol.
Inductance
100 MHz
L
82
nH
±5%
Q-factor
350 MHz
Q
60
min.
DC Resistance
Rated current
Self resonant frequency
@ 20°C
∆T = 15 K
RDC
0.18
Ω
max.
IR
1000
mA
max.
fres
1100
MHz
min.
E General information:
It is recommended that the temperature of the part does not exceed 125°C
under worst case operating conditions.
•Ambient temperature: -40°C to +110°C (refering to IR)
•Operating temperature: -40°C to +125°C
•Storage temperature (on tape & reel): -10°C to +40°C; 30 to 70% RH max.
•Test conditions of Electrical Properties: 20°C, 33% RH
if not specified differently
DESCRIPTION
Reference on drawing
Marking
Description
82N (Inductance Code)
2.3
2016-06-20
KaS
HBH
Würth Elektronik eiSos GmbH & Co. KG
2.2
2015-07-15
SSt
HBH
EMC & Inductive Solutions
Max-Eyth-Str. 1
2.1
2014-09-15
SSt
HBH
74638 Waldenburg
2.0
2014-04-09
SSt
Germany
HBH
Tel. +49 (0) 79 42 945 - 0
1.0
2004-10-11
AWe
-
www.we-online.com
eiSos@we-online.com
REV
DATE
BY
CHECKED
WE-KI SMD Wire Wound Ceramic Inductor
Order.- No.
SIZE
744762182A
A4
Size: 1008A
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use.
Moreover Würth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before
the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.