English
Language : 

7447471104 Datasheet, PDF (1/6 Pages) Wurth Elektronik GmbH & Co. KG, Germany. – WE-TIS Shielded Radial Leaded Wire Wound Inductor
A Dimensions: [mm]
B Recommended hole pattern: [mm]
C Schematic:
D Electrical Properties:
Properties
Test conditions
Value Unit
Inductance
1 kHz/ 5 mA
L
100000 µH
Rated current
∆T = 40 K
IR
0.05
A
Saturation current
|ΔL/L| < 10%
Isat
0.05
A
DC Resistance
RDC
210
Ω
DC Resistance
RDC
175
Ω
Self resonant frequency
fres
0.09
MHz
Tol.
±10%
max.
typ.
max.
typ.
typ.
E General information:
It is recommended that the temperature of the part does not exceed 125°C un-
der worst case operating conditions.
Ambient temperature: -40°C to +85°C (refering to IR)
Operating temperature: -40°C to +125°C
Storage temperature (in tray packaging): -20°C to +40°C; 75% RH max.
Test conditions of Electrical Properties: 20°C, 33% RH
if not specified differently
DESCRIPTION
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
1.1
2012-06-28
SSt
Germany
SSt
Tel. +49 (0) 79 42 945 - 0
1.0
2011-10-01
SSt
CZ
www.we-online.com
eiSos@we-online.com
REV
DATE
BY
CHECKED
WE-TIS Shielded Radial Leaded Wire
Wound Inductor
Order.- No.
SIZE
7447471104
A4
Size: 1111
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use.
Moreover Würth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before
the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.