English
Language : 

74435581200 Datasheet, PDF (1/6 Pages) Wurth Elektronik GmbH & Co. KG, Germany. – WE-HCI SMD Flat Wire High Current Inductor
A Dimensions: [mm]
B Recommended land pattern: [mm]
C Schematic:
D Electrical Properties:
Properties
Test conditions
Value Unit Tol.
Inductance
100 kHz/ 10 mA
L
12
µH ±20%
Rated inductance 100 kHz/ 10 mA/ 19.0 A LR
8.9
µH
typ.
Rated current
∆T = 50 K
IR
19.0
A
max.
Saturation current
|ΔL/L| < 30%
Isat
25.0
A
typ.
DC Resistance
@ 20°C
RDC 4.30 mΩ ±10%
Self resonant frequency
fres
13
MHz typ.
E General information:
It is recommended that the temperature of the part does not exceed 125°C
under worst case operating conditions.
Ambient temperature: -40°C to +85°C (refering to IR)
Operating temperature: -40°C to +125°C
Storage temperature (on tape & reel): -20°C to +40°C; 75% RH max.
Test conditions of Electrical Properties: 20°C, 33% RH
if not specified differently
DESCRIPTION
1.4
2012-12-06
SSt
SSt
Würth Elektronik eiSos GmbH & Co. KG
1.3
2012-10-24
SSt
BD
EMC & Inductive Solutions
Max-Eyth-Str. 1
1.2
2012-08-08
SSt
BD
74638 Waldenburg
1.1
2012-06-28
SSt
Germany
SSt
Tel. +49 (0) 79 42 945 - 0
1.0
2012-03-12
SSt
DDe
www.we-online.com
eiSos@we-online.com
REV
DATE
BY
CHECKED
WE-HCI SMD Flat Wire High Current
Inductor
Order.- No.
SIZE
74435581200
A4
Size: 2212
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use.
Moreover Würth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before
the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.