English
Language : 

744323150 Datasheet, PDF (1/6 Pages) Wurth Elektronik GmbH & Co. KG, Germany. – WE-HCI SMD Flat Wire High Current Inductor
A Dimensions: [mm]
B Land Pattern: [mm]
C Schematic:
D Electrical Properties:
Properties
Test conditions
Inductance
100 kHz/ 100 mV
L
Rated inductance 100 kHz/ 100 mV/ 12.0 A LR
Rated current
∆T = 50 K
IR
Saturation current
|ΔL/L| < 30%
Isat
DC Resistance
@ 20°C
RDC
Self resonant frequency
fres
Value
1.5
1.28
12.0
18.0
6.6
43
Unit Tol.
µH ± 20%
µH
typ.
A
max.
A
typ.
mΩ ±10%
MHz typ.
E General information:
It is recommended that the temperature of the part does not exceed 150°C
under worst case operating conditions.
Ambient temperature: -40°C to +100°C (refering to IR)
Operating temperature: -40°C to +150°C
Storage temperature (on tape & reel): -20°C to +40°C; 75% RH max.
Test conditions of Electrical Properties: 20°C, 33% RH
if not specified differently
DESCRIPTION
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
2.0
2012-09-03
SSt
Germany
BD
Tel. +49 (0) 79 42 945 - 0
1.0
2008-08-23
RST
www.we-online.com
eiSos@we-online.com
REV
DATE
BY
CHECKED
WE-HCI SMD Flat Wire High Current
Inductor
Order.- No.
SIZE
744323150
A4
Size: 1030
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use.
Moreover Würth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before
the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.