A Dimensions: [mm]
B Recommended land pattern: [mm]
C Schematic:
D Electrical Properties:
Properties
Test conditions
Value Unit
Tol.
Impedance @ 25 MHz
25 MHz
Z
425
Ω
typ.
Impedance @ 100 MHz
100 MHz
Z
580
Ω
±25%
Rated current
DC Resistance
ΔT = 40K
@ 20°C
IR
5.0
RDC
12
A
max.
mΩ
max.
E General information:
Do not use this part beyond the Rated Current, as this will create
excessive heat and can harm the component
•Curie Temperature: +140°C
•Storage Temperature (on Tape & Reel): -40°C to +40°C
•Operating Temperature: -40°C to +125°C
•Test conditions of Electrical Properties: 20°C, 33% RH
if not specified differently
DESCRIPTION
7.9
2014-01-08
SSt
7.8
2014-06-05
SSt
7.7
2014-01-02
SSt
7.6
2013-04-18
SSt
7.5
2013-01-22
SSt
7.4
2012-12-04
SSt
7.3
2012-10-23
SSt
7.2
2012-09-27
SSt
MHB
SSt
SSt
Würth Elektronik eiSos GmbH & Co. KG
SSt
EMC & Inductive Solutions
Max-Eyth-Str. 1
SMu
74638 Waldenburg
Germany
SSt
Tel. +49 (0) 79 42 945 - 0
SMu
www.we-online.com
eiSos@we-online.com
SMu
WE-SUKW SMD EMI Suppression 5-Hole
Ferrite Bead
Order.- No.
SIZE
7427512
A4
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use.
Moreover Würth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before
the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.