156120VS82500 Datasheet, PDF (1/7 Pages) Wurth Elektronik GmbH & Co. KG, Germany. – WL-SMRW SMD Mono-color Reverse mount Waterclear
Dimensions: [mm]
Polarity Mark
1
(Cathode) 2
0,6 typ.
3,2 ±0,1
1,62 ±0,1
0,6 typ.
Recommended Land Pattern: [mm]
normal
use
1,5
1
0,8
reverse
use
2,0
1,5
2
2,6
0,8
O 2,4
Scale - 10:1
Absolute Maximum Ratings (Ambient Temperature 25°C):
Properties
Value
Unit
Power Dissipation
Peak Forward Current
Continuous Forward Current
Reverse Current
PDISS
IF Peak
IF
IREV
48
mW
40
mA
20
mA
100
µA
ESD Threshold/ Human Body
Model
VESD HBM
1000
V
Optical Properties:
Chip Technology
Emitting Color
Lens Type
AlInGaP
Bright Green
Dome
Schematic:
General Information:
Operating Temperature
-40 °C up to +85 °C
Storage Temperature (in original
packaging)
-40 °C up to +85 °C; 60% RH max.
-
1
+
2
Moisture Sensitive Level
MSL
3
Polarity Mark
(Cathode)
Scale - 10:1
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CREATED
KaS
CHECKED
PLD
GENERAL TOLERANCE
DIN ISO 2768-1m
PROJECTION
METHOD
DESCRIPTION
WL-SMRW SMD Mono-color
Reverse mount Waterclear
ORDER CODE
156120VS82500
SIZE
REVISION
STATUS
1206 dome 001.001
Valid
DATE
BUSINESS UNIT
PAGE
2016-11-23
eiPal
1/7
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety