English
Language : 

WM9713 Datasheet, PDF (7/111 Pages) Wolfson Microelectronics plc – AC 97 AUDIO + TOUCHPANEL CODEC
Preliminary Technical Data
WM9713L
ABSOLUTE MAXIMUM RATINGS
Absolute Maximum Ratings are stress ratings only. Permanent damage to the device may be caused by continuously operating at
or beyond these limits. Device functional operating limits and guaranteed performance specifications are given under Electrical
Characteristics at the test conditions specified.
ESD Sensitive Device. This device is manufactured on a CMOS process. It is therefore generically susceptible
to damage from excessive static voltages. Proper ESD precautions must be taken during handling and storage
of this device.
Wolfson tests its package types according to IPC/JEDEC J-STD-020B for Moisture Sensitivity to determine acceptable storage
conditions prior to surface mount assembly. These levels are:
MSL1 = unlimited floor life at <30°C / 85% Relative Humidity. Not normally stored in moisture barrier bag.
MSL2 = out of bag storage for 1 year at <30°C / 60% Relative Humidity. Supplied in moisture barrier bag.
MSL3 = out of bag storage for 168 hours at <30°C / 60% Relative Humidity. Supplied in moisture barrier bag.
The Moisture Sensitivity Level for each package type is specified in Ordering Information.
CONDITION
Digital supply voltages (DCVDD, DBVDD)
Analogue supply voltages (AVDD, HPVDD, TPVDD)
Speaker supply voltage (SPKVDD)
Touchpanel supply voltage (TPVDD)
Voltage range digital inputs
Voltage range analogue inputs
Voltage range touchpanel Inputs X+, X-, Y+ and Y-
Voltage range touchpanel Inputs X+, X-, Y+ and Y-
Operating temperature range, TA
Storage temperature (TQFP package only)
MIN
-0.3V
-0.3V
-0.3V
DGND -0.3V
AGND -0.3V
-25oC
-65oC
MAX
+3.63V
+3.63V
+4.2V
AVDD +0.3V
DBVDD +0.3V
AVDD +0.3V
TPVDD +0.3V
AVDD +0.3V
+85oC
+150oC
RECOMMENDED OPERATING CONDITIONS
PARAMETER
SYMBOL
TEST CONDITIONS
MIN
TYP
Digital input/output buffer supply
range
Digital core supply range
DBVDD
DCVDD
Analogue supply range
Speaker supply range
Digital ground
Analogue ground
Difference AGND to DGND
AVDD, HPVDD,
TPVDD
SPKVDD
DGND1, DGND2
AGND, HPGND,
SPKGND, TPGND
Note 1
1.62
3.3
(target)
1.62
1.8
(target)
1.8
3.3
1.8
3.3
0
0
-0.3
0
Note:
1. AGND is normally the same as DGND1/DGND2
2. DCVDD <= DBVDD and DCVDD <= AVDD
MAX
3.6
3.6
3.6
4.2
+0.3
UNIT
V
V
V
V
V
V
V
1
PTD, March 2004, Rev 2.2
7