WM8802 Datasheet, PDF (43/65 Pages) Wolfson Microelectronics plc – Digital Audio Interface Transceiver
Product Preview
REGISTER ADDRESS
CCB address: 0xE8;
Command address: 2
Master clock setting:
DI7
DI6
DI5
DI4
0
0
1
0
DI15
DI14
DI13
DI12
AMPOPR1 AMPOPR0 EXSYNC PLLOPR
DI3
0
DI11
XMSEL1
DI2
0
DI10
XMSEL0
WM8802
DI1
DI0
CAU
CAL
DI9
XINSEL
DI8
PLLSEL
PLLSEL
XINSEL
XMSEL [1:0]
PLLOPR
EXSYNC
AMPOPR [1:0]
PLL lock frequency setting
0: 512fs (fs ≤ 96kHz commend) (initial value)
1: 256fs
XIN input frequency setting
0: 12.288MHz (initial value)
1: 24.576MHz
XMCK output frequency setting
00: 1/1 of XIN input frequency (initial value)
01: 1/2 of XIN input frequency
10: Reserved
11: Muted
PLL (VCO) operation setting
0: Operate (initial value)
1: Stop
PLL unused demodulation function (external synchronization function)
setting
0: PLL usage normal operation (initial value)
1: PLL unused external synchronization operation (supply 256fs clock to
TMCK)
Oscillation amplifier operation setting
00: Automatic stopping of oscillation amplifier during PLL lock (initial value)
01: Normal continuous operation
10: Reserved
11: Stop
If the PLL is stopped with PLLOPR during PLL lock, the output clocks are all muted.The muted
status continues even if the PLL becomes unlocked.
RERR goes to into error status, while the PLL is locked, if the permanent continuous operation
setting is set using AMPOPR[0:1]. However, the RERR status can be maintained if no PLL error is
output and if the sampling frequency changes when FSERR is set.
Sampling frequency calculation is not performed when the oscillation amplifier automatic stop mode
is set using AMPOPR[0:1]; even if the input sampling frequency changes within the capture range of
the PLL and no lock error occurs. The input data sampling frequency and the fs calculation result
may differ. However, if the channel status sampling frequency information is rewritten together with
input data changes, this information is reflected to the error flag and fs calculation of the input data is
performed. Since the oscillation amplifier continuous operation setting allows permanent fs
calculation, sampling frequency changes are always reflected to the error flag.
w
PP Rev 1.1 April 2004
43