English
Language : 

WM8350 Datasheet, PDF (41/340 Pages) Wolfson Microelectronics plc – Wolfson AudioPlus™ Stereo CODEC with Power Management
Production Data
Figure 27 Multiple Register Write to Specified Address using Auto-increment
WM8350
Figure 28 Multiple Register Read from Specified Address using Auto-increment
Figure 29 Multiple Register Read from Last Address using Auto-increment
Multiple Write and Multiple Read operations enable the host processor to access sequential blocks of
the data in the WM8350 register map faster than is possible with single register operations. The
Auto-Increment function is enabled by default; this is controlled by the AUTOINC register bit as
described in Table 3.
ADDRESS
R6 (06h)
Interface Control
BIT LABEL
9 AUTOINC
DEFAULT
1
Table 3 Enabling Address Auto-Increment
DESCRIPTION
Enables address auto-increment
0 = disabled
1 = enabled
w
PD, February 2011, Rev 4.4
41