English
Language : 

MH204 Datasheet, PDF (1/2 Pages) WJ Communication. Inc. – High Dynamic Range Cellular Band MMIC Mixer
MH204
High Dynamic Range Cellular Band MMIC Mixer
The Communications Edge TM
Advanced Product Information
Product Features
Product Description
Functional Diagram
• +30 dBm IIP3
• RF 890 – 960 MHz
• LO 1190 – 1310 MHz
• IF 300 – 350 MHz
• +17 dBm Drive Level
• Low Cost SOIC-8 Package
• No External Bias Required
Specifications
Parameters1
The MH204 is a passive GaAs MESFET mixer that
provides high dynamic range performance in a low
cost SOIC-8 package. WJ’s MH204 uses patented
techniques to realize greater than +30 dBm Input
IP3 at an LO drive level of +17 dBm when used in a
simple application circuit as an upconverting or
downconverting configuration. This single
monolithic integrated circuit does not require any
external baluns or bias elements.
Typical applications include frequency up/down
conversion, modulation and demodulation for
receivers and transmitters used in 2.5G and 3G
systems using the cellular and GSM frequency
bands.
1
8
2
7
3
6
4
5
Function
LO
IF & RF*
GND
Pin No.
2
5
1,3,4,6,8
* 4 external components (inductors & capacitors)
are required to diplex the signal
Units
Minimum Typical Maximum
Comments
Frequency Range:
RF
LO
IF
SSB Conversion Loss
Noise Figure
Input IP32
Input P1dB
Isolation:
L-R
L-I
R-I
Return Loss:
LO Port
LO Drive Level
MHz
MHz
MHz
dB
dB
dBm
dBm
dB
dB
dB
dB
dBm
890
960
1190
1310
300
350
9.0
9.5
9.5
+30
TBD
25
50
TBD
-8
+17
1. Data was taken using an application board shown on the following page, with a high side LO at +17 dBm in an downconverting application at 25°C.
2. Input IP3 was measured with two tones with an input power of -5 dBm / tone separated by 1 MHz.
Absolute Maximum Rating3
Application Circuit
Parameters
Rating
Operating Case Temperature
-40° to +85 °C
LO
Storage Temperature
-65° to +100 °C
Maximum Input LO Power4
+21 dBm
3. Operation of this device above any of these parameters may cause permanent damage.
4. Total sum of LO port and RF port power should not to exceed +23 dBm.
L1
23 nH
C2
3.9 pF
RF
IF
C1
8.2 pF
L2
12 nH
All components are of size 0402
WJ Communications, Inc • Phone 1-800-WJ1-4401 • FAX: 408-577-6620 • e-mail: sales@wj.com • Web site: www.wj.com
April 2002