English
Language : 

W77LE516 Datasheet, PDF (60/89 Pages) Winbond – 8-BIT MICROCONTROLLER
W77LE516/W77L516A
The 16 states of the counter effectively divide the bit time into 16 slices. The bit detection is done on a
best of three basis. The bit detector samples the RxD pin, at the 8th, 9th and 10th counter states. By
using a majority 2 of 3 voting system, the bit value is selected. This is done to improve the noise
rejection feature of the serial port. If the first bit detected after the falling edge of RxD pin is not 0, then
this indicates an invalid start bit, and the reception is immediately aborted. The serial port again looks
for a falling edge in the RxD line. If a valid start bit is detected, then the rest of the bits are also
detected and shifted into the SBUF.
After shifting in 8 data bits, there is one more shift to do, after which the SBUF and RB8 are loaded
and RI is set. However certain conditions must be met before the loading and setting of RI can be
done.
1. RI must be 0 and
2. Either SM2 = 0, or the received stop bit = 1.
If these conditions are met, then the stop bit goes to RB8, the 8 data bits go into SBUF and RI is set.
Otherwise the received frame may be lost. After the middle of the stop bit, the receiver goes back to
looking for a 1-to-0 transition on the RxD pin.
Timer 1
Overflow
Timer 2 Overflow
(for Serial Port 0 only)
Internal
2
Write to
Data Bus
SBUF
SMOD=
(SMOD_1) 0
1
TCLK 0 1
16
TX START TX SHIFT
TX CLOCK
TI
RCLK
01
16
SERIAL
CONTROLLER RI
SAMPLE
1-TO-0
DETECTOR
RX CLOCK
RX
START
LOAD
SBUF
RX SHIFT
Transmit Shift Register
STOP
PARIN
START SOUT
LOAD
CLOCK
RXD
BIT
DETECTOR
CLOCK
PAROUT
SBUF
SIN
D8
RB8
Receive Shift Register
TXD
Serial Port
Interrupt
Read
SBUF
Internal
Data
Bus
Figure 21. Serial Port Mode 1
MODE 2
This mode uses a total of 11 bits in asynchronous full-duplex communication. The functional
description is shown in the figure below. The frame consists of one start bit (0), 8 data bits (LSB first),
a programmable 9th bit (TB8) and a stop bit (0). The 9th bit received is put into RB8. The baud rate is
programmable to 1/32 or 1/64 of the oscillator frequency, which is determined by the SMOD bit in
PCON SFR. Transmission begins with a write to SBUF. The serial data is brought out on to TxD pin at
C1 following the first roll-over of the divide by 16 counter. The next bit is placed on TxD pin at C1
- 60 -