English
Language : 

W29GL064C_13 Datasheet, PDF (59/68 Pages) Winbond – 64M-BIT 3.0-VOLT PARALLEL FLASH MEMORY WITH PAGE MODE
W29GL064C
8.6 Recommended Operating Conditions
8.6.1 At Device Power-up
AC timing illustrated in Figure A is recommended for the supply voltages and the control signals at
device power-up. If the timing in the figure is ignored, the device may not operate correctly.
VCC(min)
VCC
GND
tVR
tVCS
VIH
#CE
VIL
tF
tCE
tR
VIH
#WE
VIL
VIH
#OE
VIL
VIH
ADDRESS
VIL
tF
tOE
tR or tF
tAA
VALID ADDRESS
tR
tR or tF
DATA
VOH
VOL
High Z
Valid Data
Out
VIH
#WP/ACC
VIL
Figure 8-28 AC Timing at Device Power-Up
Description
SYMBOL
MIN
VCC Rise Time
tVR
20
Input Signal Rise Time
tR
Input Signal Fall Time
tF
VCC Setup Time
tVCS
35
Table 8-9
AC Characteristics at Device Power Up
MAX
500,000
20
20
UNIT
µs/V
µs/V
µs/V
µs
Publication Release Date: August 2, 2013
53
Revision H