W27E040 Datasheet, PDF (5/15 Pages) Winbond – 512K X 8 ELECTRICALLY ERASABLE EPROM
W27E040
AC CHARACTERISTICS
AC Test Conditions
PARAMETER
Input Pulse Levels
Input Rise and Fall Times
Input and Output Timing Reference Level
Output Load
AC Test Load and Waveform
CONDITIONS
0.45V to 2.4V
10 nS
0.8V/2.0V
CL = 100 pF, IOH/IOL = -0.4 mA/2.1 mA
DOUT
+1.3V
(IN914)
3.3K ohm
100 pF (Including Jig and Scope)
Input
2.4V
0.45V
Test Points
2.0V
0.8V
Output
2.0V
0.8V
Test Points
Publication Release Date: May 1997
-5-
Revision A1