English
Language : 

W83783S Datasheet, PDF (49/57 Pages) Winbond – MONITORING IC
W83783S
7.35 Reserved Register -- Index 50h--52h (BANK4)
7.36 BEEP Control Register 3 -- Index 53h (Bank 4)
Register Location:
Power on Default Value
Attribute:
Size:
53h
<7:0> 0000,0000. Reset by MR.
Read/Write
8 bits
7 6 5 4 32 1 0
Preliminary
Reserved
Reserved
Reserved
Reserved
Reserved
EN_USER_BP
Reserved
Reserved
Bit 7-6: Reserved.
Bit 5: User define BEEP output function. Write 1, the BEEP is always active. Write 0, this function is
inactive. (Default 0)
Bit 4-0: Reserved.
7.37 Reserved Register -- Index 54h--58h (Bank 4)
7.38 Real Time Hardware Status Register I -- Index 59h (Bank 4)
Register Location:
59h
Power on Default Value
<7:0> 0000,0000. Reset by MR.
Attribute:
Read Only
Size:
8 bits
7 6 5 4 32 1 0
VCORE_STS
Reserved
+3.3VIN_STS
+5VIN_STS
TEMP2_STS
TEMP1_STS
FAN1_STS
FAN2_STS
- 43 -
Publication Release Date: April 1999
Revision 0.55