English
Language : 

W91473 Datasheet, PDF (12/20 Pages) Winbond – 14-MEMORY TONE/PULSE SWITCHABLE DIALER WITH HANDFREE AND LOCK FUNCTION
W91473 SERIES
MERCURY DIALING
1. Up to 32 digits may be stored.
2. Mercury dialing is activated only as the first key-in after off-hook or handfree dialing is activated.
3. The timing diagram for the mercury memory function is given below.
KEY IN
DP
T/P MUTE
MER
TP
TIDP
DTMF
HPM MUTE
OSC.
OSCILLATION
Mercury Function Timing Diagram
ABSOLUTE MAXIMUM RATINGS
PARAMETER
SYMBOL
RATING
UNIT
DC Supply Voltage
VDD−VSS
-0.3 to +7.0
V
Input/Output Voltage
VIL
VSS -0.3
V
VIH
VDD +0.3
V
VOL
VSS -0.3
V
VOH
VDD +0.3
V
Power Dissipation
PD
120
mW
Operating Temperature
TOPR
-20 to +70
°C
Storage Temprature
TSTG
-55 to +125
°C
Note: Exposure to conditions beyond those listed under Absolute Maximum Ratings may adversely affect the life and reliability
of the device.
- 12 -