English
Language : 

LANC2405DW12 Datasheet, PDF (9/14 Pages) Wall Industries,Inc. – DC/DC Converter 18-36 VDC Input ±5.0 VDC Output at ±1.2A
TECHNICAL DATASHEET
LANC2405DW12
EMC Considerations
Suggested Schematic for EN55022 Conducted Emission Class A Limits
Figure 11
Recommended Layout with Input Filter
Figure 12
To meet Conducted Emissions EN55022 CLASS A needed the following components:
Component
C1
C2, C3
LANC12xxDW12
Value
Voltage
6.8uF
50V
1000pF
2KV
Reference
1210 MLCC
1206 MLCC
Component
C1
C2, C3
LANC24xxDW12
Value
Voltage
4.7uF
50V
1000pF
2KV
Reference
1210 MLCC
1206 MLCC
Component
C1
C2, C3
LANC48xxDW12
Value
Voltage
2.2uF
100V
1000pF
2KV
Reference
1812 MLCC
1206 MLCC
(888) 597-WALL
www.wallindustries.com
Page 9 of 14