English
Language : 

LANC1205DW8 Datasheet, PDF (9/14 Pages) Wall Industries,Inc. – DC/DC Converter 9-18 VDC Input ±5.0 VDC Output at ±0.8A
TECHNICAL DATASHEET
LANC1205DW8
EMC Considerations
Suggested Schematic for EN55022 Conducted Emission Class A Limits
Figure 11
Recommended Layout with Input Filter
Figure 12
To meet Conducted Emissions EN55022 CLASS A needed the following components:
Component
C1
C2, C3
LANC12xxDW8
Value
Voltage
4.7uF
25V
1000pF
2KV
Reference
1210 MLCC
1206 MLCC
Component
C1
C2, C3
LANC24xxDW8
Value
Voltage
N/A
---
1000pF
2KV
Reference
---
1206 MLCC
Component
C1
C2, C3
LANC48xxDW8
Value
Voltage
N/A
---
1000pF
2KV
Reference
---
1206 MLCC
(888) 597-WALL
www.wallindustries.com
Page 9 of 14