TECHNICAL DATASHEET
JFW48S15-1000
TEST SETUP:
The JFW48S15-1000 specifications are tested with the following configurations:
Input Reflected-Ripple Current Measurement Test Setup
Figure 8
Component
L
C
C
Value
12µH
220µF
33µF
Voltage
----
100V
100V
Reference
----
Aluminum Electrolytic Capacitor
Aluminum Electrolytic Capacitor
Peak-to-Peak Output Ripple & Noise Measurement Setup
Figure 9
Output Voltage and Efficiency Measurement Setup
Figure 10
Efficiency
=


Vout
Vin
×
×
Iout
Iin


×100%
NOTE: All measurements are taken at the module terminals