EMC RECOMMNEDED CIRCUIT
Rev A
PSLS05C SERIES
5 Watts
AC/DC Converter
Single Output
Figure 3: Recommended circuit for applications which require higher EMC standard.
EMC RECOMMNEDED CIRCUIT PCB LAYOUT
Figure 4: EMC application circuit PCB layout
Safety and Recommended Wiring: linewidth ≥3mm, line-line distance≥6mm, line-ground distance ≥6mm, A≥6.4mm
EXTERNAL CIRCUIT PARAMETERS
Model
C1
C2
L1
C3
(Required) (Required) (Required) (Required)
CX1
C4
PSLS05C-15B03S(-F)
PSLS05C-15B05S(-F)
470µF/10V
470µF/16V 0.47uH 150µF/35V
CY0
FUSE
(Required)
TVS
SMBJ7.0A
PSLS05C-15B09S(-F)
PSLS05C-15B12S(-F)
PSLS05C-15B15S(-F)
PSLS05C-15B24S(-F)
22µF/400V
300µF/25V
100µF/35V
1uH
4.7uH
150µF/35V
0.1µF/275VAC
100nF/50V
1nF/400
VAC
1A/250V
47µF
SMBJ12A
SMBJ20A
SMBJ30A
Notes:
1. C1, C2, and C3 are electrolytic capacitors. They are required for both AC input and DC input,
When AC input, C1 is used as filter capacitor, the value of C1 is recommended to be 22µF/400V. When DC input, C1 is used as EMC filter capacitor, the
value of C1 is recommended to be 10µF/400V (when the input voltage is above 370VDC, the recommended value of C1 is 10µF/450V). C2 and C3 are
output filer capacitors, they are recommended to be high frequency and low impedance electrolytic capacitors. Capacitance and rated ripple current of
capacitors refer to the datasheets provided. Voltage derating of capacitors should be 80% or above. C4 is a ceramic capacitor, which is used to filter
high frequency noise. C2, C3 and L1 form a pi-type filter circuit. Current of L1 refer to the datasheets provided by the manufacturers, current derating
should be 80% or above. To protect post-circuits (if converter fails), TVS is recommended. External NTC thermistor is recommended to be 5D-9.
External input MOV is recommended to use S14K350.
2. For Standard EMC requirement, please refer to figure 1. If higher EMC requirement, please refer to figure 3, recommended parameters are shown in
table below.
Recommended Parameter for Higher EMC Standard Circuit
Components
Recommend Parameter
MOV2
S10K300
CY1, CY2
1nF/400VAC
CX
0.1µF/275VAC
LCM
3.5mH
LDM
5mH
FC-L01DV1
1KV/2KV Surge Protector
FUSE
1A/250V, slow blow, it must be connected to FUSE
11/4/2016
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: sales@wallindustries.com