FUNCTION DESCRIPTION OF CN4
Pin Number
C1
C2
C3
C4
C5
C6
C7
C8
Function
+S
-S
CS
GND
GND
+RC
+PG
+5V-AUX
Description
Current Share Function Pins
This pin connects to the negative terminal (-V). Return for DC-OK signal output.
This pin connects to the negative terminal (-V). Return for DC-OK signal output.
Turns the output ON and OFF by electrical or dry contact between pin C4 (-RC), Short: Power OFF, Open: Power ON
DC-OK Signal is a DC output, referenced to pin 6 (DC-OK GND).
Stand-by voltage output ground 4.5~5V, referenced to pin C4 or C5 (GND). The maximum load current is 0.6A
FUNCTION MANUAL
1. DC-OK Signal
Between DC-OK (pin C5) and GND (pin C6)
4~6V
0~1V
Output Status
ON
OFF
C7
C1
C8
C2
C7
+PG GND CS
+5V
-AUX
+RC
GND
C8
C1
+S
-S
C2
2. Remote Control
It can be turned ON/OFF by using the “Remote Control” function.
Between RC+ (pin C3) and RC- (pin C4)
SW ON (Short)
SW OFF (Open)
Output Status
OFF
ON
C7
C1
C8
C2
C7
+PG GND CS
+5V
-AUX
+RC
GND
C8
C1
+S
-S
C2
SW
3. Current Sharing
1. The difference of Vout among parallel units should be less than ±1%.
2. The power Pout should be less than 50%.
3. Three units is the maximum when in in parallel operation.
4. The power supplies should be connected in parallel to the load using short and large diameter wiring (twisted is ideal).
CS +S
-S
CS +S
-S
CS +S
-S
01/15/2013
+S +
(Pin C1)
Load
_
-S
(Pin C2)
C7
+PG
+5V
-AUX
C8
CN4
GND CS
+RC GND
C1
+S
-S
C2
Sense lines should be twisted in pairs
Wall Industries, Inc. • 5 Watson Brook Road, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797
website: www.wallindustries.com • e-mail: sales@wallindustries.com