English
Language : 

JFC10 Datasheet, PDF (4/5 Pages) Wall Industries,Inc. – 10 Watt DC/DC Power Converters
Wall Industries, Inc.
Rev B
JFC10 SERIES
10 Watt DC/DC Power Converters
DERATING & EFFICIENCY CURVES
JFC48S05-10 Derating Curve
120
100
80
60
Natural Convection
40
100LFM
200LFM
20
300LFM
400LFM
500LFM
0
-40 -20
0
20
40
60
80 100 120
Ambient Temperature (°C)
JFC48S05-10 Efficiency vs Input Voltage
93
89
85
81
77
73
69
36 40 44 48 52 56 60 64 68 72 75
Input Voltage (VDC)
JFC48S05-10 Derating Curve with Heatsink
120
100
80
60
Natural Convection
40
100LFM
200LFM
20
300LFM
400LFM
500LFM
0
-40 -20
0
20
40
60
80 100 120
Ambient Temperature (°C)
JFC48S05-10 Efficiency vs Output Load
93
89
85
81
77
Vin= 36V
73
Vin= 48V
Vin= 75V
69
10 20 30 40 50
60 70 80 90 100
% of Full Load
MECHANICAL DRAWING
SIDE VIEW
DIA.
0.04 (1.0)
1.00 (25.4)
0.800 (20.32)
6
3
2
5
1
BOTTOM
4
VIEW
PIN CONNECTIONS
PIN
SINGLE
DUAL
1
+INPUT
+INPUT
2
-INPUT
-INPUT
3
CTRL
CTRL
4
+OUTPUT
+OUTPUT
5
TRIM
COMMON
6
-OUTPUT
-OUTPUT
NOTES
1. Unit: inches (mm)
2. Tolerance: X.XX±0.02 (X.X±0.5)
X.XXX±0.01 (X.XX±0.25)
3. Pin Pitch Tolerance: ±0.01 (±0.25)
4. Pin Dimension Tolerance: ±0.004 (±0.1)
5. All dimensions are for reference only
PRODUCT OPTIONS
OPTION
Positive Logic Remote On/Off
Negative Logic Remote On/Off
Without CTRL Pin
Without CTRL and TRIM Pins
Positive Logic without TRIM Pin
Negative Logic without TRIM Pin
Heatsink
SUFFIX
None
R
D
G
F
RF
HC
EXTERNAL OUTPUT TRIMMING
Output can be externally trimmed by using the
method shown below
TRIM UP
6
TRIM DOWN
5
RU
5
RD
4
02/03/2014
Wall Industries, Inc. • 5 Watson Brook Road, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797
website: www.wallindustries.com • e-mail: sales@wallindustries.com
Page 4 of 5