English
Language : 

PSRL5016X3 Datasheet, PDF (2/3 Pages) Wall Industries,Inc. – AC/DC Switching Power Supply
PSRL5016X3 Series
Active PFC
300 Watt Single Output
AC/DC Switching Power Supply
SPECIFICATIONS (CONTINUED)
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
0°C to +70°C ambient, de-rating at 2.5% per degree from 50°C to 70°C.
Storage Temperature
-20°C to +85°C
Operating Humidity
5% to 90% RH, non-condensing
Storage Humidity
5% to 95% RH, non-condensing
Vibration
Cooling
5 ~ 50Hz, acceleration 7.35 m/(s x s) on X, Y, and Z Axis.
U Type (U-Chassis): 22CFM forced airflow to achieve maximum power.
E Type (Enclosed with built-in fan): Self cooled by built-in fan.
Fan Drive
12VDC/400mA is available to drive an external fan.
MTBF
PHYSICAL SPECIFICATIONS
Weight
Dimensions
SAFETY
100,000 hours (according to MIL-HBK-217F) at 30°C.
U Type (U-Chassis): 950g
E Type (Enclosed with built-in fan): 1050g
U Type (U-Chassis): 7(L) x 4(W) x 2(H) inches.
E Type (Enclosed with built-in fan): 8(L) x 4(W) x 2(H) inches.
Emissions
FCC part15, CISPR 22 Class B, Conducted.
Safety Regulations
Approved to UL60950-1, CSA C22.2 No. 60950-1-03, TUV EN60950-1, CE Mark (LVD) EN61000-3-2,3, &
IEC61000-4 Series Regulations and CB.
MODEL SELECTION TABLE
Model
PSRL5016U3-12
PSRL5016U3-18
PSRL5016U3-24
PSRL5016U3-36
PSRL5016U3-48
Output Voltage Range
12 - 15 VDC
16 - 21 VDC
22 - 30 VDC
31 - 41 VDC
42 - 55 VDC
U-Chassis Models (U Type)
Preset Voltage Output Current
12 VDC
25A
18 VDC
18.75A
24 VDC
13.64A
36 VDC
9.68A
48 VDC
7.15A
Regulation
±1%
±1%
±1%
±1%
±1%
Ripple & Noise
±1%
±1%
±1%
±1%
±1%
Model
PSRL5016E3-12
PSRL5016E3-18
PSRL5016E3-24
PSRL5016E3-36
PSRL5016E3-48
Enclosed with Built-in Fan Models (E Type)
Output Voltage Range Preset Voltage Output Current
12 - 15 VDC
12 VDC
25A
16 - 21 VDC
18 VDC
18.75A
22 - 30 VDC
24 VDC
13.64A
31 - 41 VDC
36 VDC
9.68A
42 - 55 VDC
48 VDC
7.15A
Regulation
±1%
±1%
±1%
±1%
±1%
Ripple & Noise
±1%
±1%
±1%
±1%
±1%
NOTES
1. E Type Models (Enclosed with built-in fan): Self-cooled by built-in fan;
U Type Models (U-Chassis): 22 CFM forced airflow to achieve maximum power.
2. Providing peak current for 500uS with standard models, longer duty duration should contact manufacture.
3. All output ranges are covered in agencies certification and preset voltage will be set as standard mode if any request other than
standard output then should contact us in advance.
4. 1% minimum load is required to maintain the ripple and regulation.
5. Ripple and noise is measured from 10KHZ to 20MHz bandwidth at output terminals with parallel 0.1µF ceramic and 22µF electrolytic
capacitors.
6. Output is fully isolated.
7. Optional Top cover available please call factory for ordering details.
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797