PSPW120 Datasheet, PDF (1/2 Pages) Wall Industries,Inc. – 120 Watts with PFC AC/DC Open Frame Power Supply | |||
|
PSPW120 Series
120 Watts with PFC
5â x 3â x 1.18â Single Output
AC/DC Open Frame Power Supply
FEATURES
â PFC > 0.9
â Single Output
â Universal AC Input
â Output Voltages from 12 to 24VDC
â 5(L) x 3(W) x 1.18(H) inches (127 x 76.2 x 30 mm)
â Over Voltage/ Over Load/ Short Circuit Protected
5(L) x 3(W) x 1.18(H) inches
SPECIFICATIONS: PSPW120 Series
All specifications apply @ ±25°C ambient unless otherwise noted
INPUT SPECIFICATIONS
ENVIRONMENTAL SPECIFICATIONS
Input Rangeâ¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦.90-264VAC
Input Frequencyâ¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦... 47-63Hz
Input Currentâ¦â¦â¦â¦â¦â¦â¦â¦â¦... 2.5A max. (RMS) @ 115VAC
Inrush Currentâ¦â¦â¦â¦ < 30A peak at 115VAC cold start @ 25°C
â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦. < 50A peak at 230VAC cold start @ 25°C
OUTPUT SPECIFICATIONS
Output Currentâ¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦ see table
Output Powerâ¦â¦â¦â¦â¦â¦â¦. 120W max with convection cooling
Output Regulationâ¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦.. see table
Ripple/Noise (20 MHz BW)â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦. 1%
Hold-up Timeâ¦.⦠16ms at 120 watt load & 115VAC nominal line
PROTECTION
Short Circuit Protectionâ¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦... Auto recover
Over Voltage Protectionâ¦â¦. Output 110%-130% above following
nominal output.
â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦ Latching type, AC Recycle
Over Load Protectionâ¦â¦â¦.. Over load protected @ 105%-150%
above following maximum rating.
GENERAL SPECIFICATIONS
Operating Temperatureâ¦â¦â¦.. 0°C to +40°C ambient derate each
output at 2.5% per degree from
+40°C to 60°C
Humidity (non-condensing)â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦ 5% to 95%
Temperature Coefficientâ¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦ ±0.04% / °C
Coolingâ¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦.. free air convection
MTBFâ¦â¦â¦ 80,000 hrs at full load and 25°C ambient temperature
PHYSICAL SPECIFICATIONS
Weightâ¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦.. 10 oz
Dimensionsâ¦â¦â¦â¦â¦â¦5 x 3 x 1.18 inches (127 x 76.2 x 30 mm)
SAFETY & EMC
Safety Standardsâ¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦ UL 60950-1
â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦..CSA C22.2 No. 60950-1
â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦TUV EN60950-1
â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦.â¦â¦â¦â¦â¦â¦â¦â¦...CB IEC 60950-1
EMC Standardsâ¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦FCC Part 15 Class B
â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦ CISPR 22 Class B
â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦ EN 55022 Class B
â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦... EN 55024
â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦.EN 61000-3-2 Class D
â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦CE
Efficiencyâ¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦. 85% typical at full load
Power Factorâ¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦...>0.9
Due to advances in technology, specifications subject to change without notice
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
|
▷ |