English
Language : 

PSIUU62 Datasheet, PDF (1/4 Pages) Wall Industries,Inc. – AC/DC Switching Power Supplies
Wall Industries, Inc.
Rev A
PSIUU62 SERIES
Up to 63 Watts, AC/DC Switching Power Supplies
FEATURES
• Class I
• Single to Quad Outputs
• RoHS Compliant
• Internal EMI Filter
• Up to 63 Watts Output Power
• Power Fail Detect (Optional)
• Over Voltage and Over Current Protection
• Wide Input Voltage Range: 81~280VAC (90~420VDC)
• -20°C to +70°C Operating Temperature Range
• 3-Pin Input Connector
• 2-Pin Input Connector Available (See PSIUU63 Series)
• UL/cUL(UL 60950-1: 2nd Edition) & TUV/GS (EN 60950-1: 2nd Edition)
Safety Approvals
• 100% Burn-in Tested
Size:
5.00 x 3.21 x 1.38 inches
127.0 x 81.6 x 35.1 mm
Weight:
15oz (425g)
DESCRIPTION
The PSIUU62 series of Class I AC/DC switching mode power supplies provides up to 63 Watts of continuous output
power in a 5.00” x 3.21” x 1.38” U-chassis package. This series has single, dual, triple, and quad output models with a
wide input voltage range of 81~280VAC (90~420VDC). These power supplies have an internal EMI filter and are
protected against over voltage and over current conditions. This series also has UL/cUL (UL 60950-1: 2nd edition) and
TUV/GS (EN 60950-1: 2nd edition) safety approvals. These units are well suited for use in industrial equipment as well as
many other applications. All models are 100% burn-in tested.
TECHNICAL SPECIFICATIONS: PSIUU62 SERIES
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
INPUT SPECIFICATIONS
Input Voltage
Input Frequency
Input Current
Inrush Current
No Load Power Consumption
OUTPUT SPECIFICATIONS
Output Voltage
Line Regulation
Load Regulation
Output Power
Output Current
Ripple & Noise (peak to peak)
Hold-up Time
Start-up Time
Transient Response Time
Temperature Coefficient
PROTECTION
Over Voltage Protection
Over Current Protection
GENERAL SPECIFICATIONS
Efficiency
Dielectric Withstanding Voltage
Isolation Resistance
Leakage Current
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Cooling
MTBF
PHYSICAL SPECIFICATIONS
Weight
Dimensions (L x W x H)
Input Connector
Output Connector
SAFETY
TEST CONDITIONS
Min
Typ
Max
Unit
Universal Input Voltage Range
Operating Input Voltage Range
Vin = 100VAC or 160VDC, Io = full load
Vin = 240VAC or 325VDC, Io = full load
Vin = 115VAC or 160VDC, Io = full load, 25°C, cold start
Vin = 230VAC or 325VDC, Io = full load, 25°C, cold start
Vin = 230VAC, Io = no load
90
264
VAC
106
250
VDC
81
280
VAC
90
420
VDC
47
63
Hz
1.6
0.8
A
35
70
A
2
W
LL to HL, full load
Vin = 230VAC or 325VDC
Vin = 85VAC or 100VDC, Io = full load
Vin = 110VAC or 160VDC, Io = full load
Vin = 100VAC or 140VDC, Io = full load
Vin = 100VAC or 140VDC, Io = Full load to half load
0~50°C
0.5
5
Outputs under 3.3VDC
Others
16
-0.05
See Table
1
6
See Table
See Table
2
1
2
5
+0.05
%
%
%
ms
s
ms
%/°C
112
132
%
110
150
%
Vin = 230VAC or 325VDC, Io = full load
Primary to Secondary
Primary to PE
Test Voltage = 500VDC
Vin = 240VAC/60Hz
70
4242
2414
50
88
%
VDC
MΩ
0.45
mA
Derating linearly from 100% Load at 50°C to 50% load at 70°C
MIL-HDBK-217F, 25°C
-20
-40
0
0
100,000
+70
+85
95
95
Free air convection
°C
°C
%
%
hours
15oz (425g)
5.00 x 3.21 x 1.38 inches (127.0 x 81.6 x 35.1 mm)
Mates with Molex housing 09-52-4054 and Molex 2478 series crimp terminal
Mates with Molex housing 09-52-4084 and Molex 2478 series crimp terminal
Safety Approvals
UL/cUL (UL 60950-1: 2nd edition); TUV/GS (EN 60950-1: 2nd edition)
02/14/2014
Wall Industries, Inc. • 37 Industrial Drive, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797
website: www.wallindustries.com • e-mail: sales@wallindustries.com
Page 1 of 4