PSGKF-200 Datasheet, PDF (1/4 Pages) Wall Industries,Inc. – Watt AC/DC Switching Power Supplies | |||
|
Wall Industries, Inc.
Rev A
PSGKF-200 SERIES
200 Watt AC/DC Switching Power Supplies
FEATURES
⢠RoHS Compliant
⢠200 Watts Output Power
⢠3000VAC I/O Isolation
⢠High Efficiency up to 87.5%
⢠Operating Altitude up to 5000M
⢠100% Full Load Burn-in Test
⢠Built-in Cooling Fan Speed Control
⢠Built-in Active PFC, PF > 0.95
⢠Adjustable Output Voltage
⢠Conformal Coating on Both Sides of PCB
⢠-25°C to +70°C Wide Operating Temperature Range
⢠All Using 105°C Long Life Electrolytic Capacitors
⢠Withstand 300VAC Surge Input for 5 Sec.
⢠Universal Input Voltage Range: 85-264VAC (120-370VDC)
⢠Over Load, Over Power, and Short Circuit Protection
⢠5V, 12V, 24V, and 48VDC Single Output Models
⢠UL60950-1 (2nd edition), IEC60950-1:2005 (2nd edition),
EN60950-1:2006 Safety Approvals
Size:
7.83 x 3.90 x 1.97 inches
199.0 x 99.0 x 50.0 mm
Weight:
2.1 lbs (950g)
DESCRIPTION
The PSGKF-200 series of AC/DC switching power supplies provides 200 Watts of output power in a
7.83â x 3.90â x 1.97â enclosed case with built-in cooling fan speed control. This series consists of
5V, 12V, 24V, and 48VDC single output models with an input voltage range of 85~264VAC
(120~370VDC). Some features include high efficiency up to 87.5%, built-in active PFC, and -25°C to
+70°C operating temperature range. This series also has short circuit, over load, and over power
protection. All models are RoHS compliant and have UL60950-1 (2nd edition), IEC60950-1:2005
(2nd edition), and EN60950-1:2006 safety approvals.
Model Number
PSGKF-200-5
Input Voltage Range
MODEL SELECTION TABLE
Output Voltage
Output Current
Min
Max
5 VDC
0A
40A
Ripple & Noise (1)
150mVp-p
Output Power
200W
Efficiency
79%
PSGKF-200-12
85 ~ 264 VAC
12 VDC
0A
16.7A
150mVp-p
200W
84%
PSGKF-200-24
(120 ~ 370 VDC)
24 VDC
0A
8.4A
200mVp-p
201.6W
86%
PSGKF-200-48
48 VDC
0A
4.2A
200mVp-p
201.6W
87.5%
NOTES
1. Ripple & noise is measured at 20MHz limited bandwidth and using a 12" twisted pair-wire terminated with a 0.1µF & 47µF capacitors in parallel.
2. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still
meets EMC directives.
DERATING CURVE
100
90
80
70
60
50
40
30
20
10
0
-25
0 10 20 30 40 50 60 70 80 90 100
Ambient Temperature (°C)
12/11/2013
Wall Industries, Inc. ⢠37 Industrial Drive, Exeter, NH 03833 ⢠Tel: 603-778-2300 ⢠Toll Free: 888-597-9255 ⢠Fax 603-778-9797
website: www.wallindustries.com ⢠e-mail: sales@wallindustries.com