English
Language : 

GA6KV Datasheet, PDF (1/7 Pages) Wall Industries,Inc. – With 6KVDC Isolation Single and Dual Output 2 Watt DC - DC Converter
GA6KV Series
With 6KVDC Isolation
Single and Dual Output
2 Watt DC/DC Converter
FEATURES
● Low Cost
● 6000VDC Isolation
● Regulated Outputs
● Low Leakage Current
● MTBF > 600,000 Hours
● Input: 5, 12, and 24VDC
● Short Circuit Protection
● Low Isolation Capacitance
● Complies with EN55022 Class A
● Output: 5, 12, 15, ±5, ±12, and ±15VDC
SPECIFICATIONS: GA6KV Series
All specifications are based on 25oC, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
Min Nom Max Unit
INPUT (Vin)
Input Voltage Range (5V input models)
4.5
5
5.5 VDC
Input Voltage Range (12V input models)
10.8
12
13.2 VDC
Input Voltage Range (24V input models)
21.6
24
26.4 VDC
Reverse Polarity Input Current
0.5 A
Input Surge Voltage (1000ms) (5V input models)
-0.7
7.5 VDC
Input Surge Voltage (1000ms) (12V input models)
-0.7
15 VDC
Input Surge Voltage (1000ms) (24V input models)
-0.7
30 VDC
Leakage Current
240VAC, 60Hz
2
µA
Reflected Ripple Current
See Table
Short Circuit Input Power
All models
2000 mW
Input Filter
All models
Pi Filter
OUTPUT (Vo)
Output Voltage Range
See Table
Output Voltage Accuracy
±2.0
±4.0 %
Output Voltage Balance
Dual Output, Balanced Loads
±2.0
±4.0 %
Load Regulation
Io = 10% to 100%
±0.5
±1.0 %
Line Regulation
Vin = Min to Max
±0.3
±0.5 %
Output Power
2
W
Output Current Range
See Table
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Over Line, Load, and Temperature
30
50
mVpk-pk
100
mVpk-pk
5
mVrms
Transient Recovery Time
50% Load Step
50 µs
Transient Response Deviation
50% Load Step
±6 %
Temperature Coefficient
±0.01 ±0.02 %/°C
PROTECTION
Over Load
120
%
Short Circuit Protection
Continuous
Input Fuse Recommendation (5V input models)
1000mA Slow-Blow Type
Input Fuse Recommendation (12V input models)
500mA Slow-Blow Type
Input Fuse Recommendation (24V input models)
250mA Slow-Blow Type
GENERAL
Efficiency
See Table
Switching Frequency
25
80 KHz
Isolation Voltage Rated
60 seconds
6000
VDC
Isolation Voltage Test
Flash Tested for 1 second
8000
VDC
Isolation Resistance
500VDC
10
GΩ
Isolation Capacitance
100KHz, 1V
20
30 pF
Internal Power Dissipation
2,000 mW
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797