English
Language : 

DTSPU63 Datasheet, PDF (1/3 Pages) Wall Industries,Inc. – 63 Watt Single Output AC/DC Desktop Power Supply
Rev B
FEATURES
● Splash Proof
● 2 Year Warranty
● Class I Insulation
● IEC-320-C14 Input Inlet
● Optional Output Connector
● CEC and Energy Star Compliance
● Approved as Limited Power Source (LPS)
● Over Voltage Protection (Crowbar Design)
● Wide Input Voltage 90 to 264VAC, 47~63Hz
● Output Voltage Available from 12VDC thru 50VDC
DTSPU63 Series
63 Watt
Single Output
AC/DC Desktop Power Supply
SPECIFICATIONS: DTSPU63 Series
All specifications are based on 25oC, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
Min Nom Max
INPUT (Vin)
Operating Voltage Range
90
264
Input Frequency
47
63
Input Current (Low Line)
Io = Full Load, Vin = 115VAC
1.6
Input Current (High Line)
Io = Full Load, Vin = 230VAC
0.7
Inrush Current (Low Line)
Io = Full Load, 25°C, Cool Start, Vin = 115VAC
12
15
Inrush Current (High Line)
Io = Full Load, 25°C, Cool Start, Vin = 230VAC
26
30
Safety Ground Leakage Current
Io = Full Load, Vin = 240VAC
0.5
0.75
Start-Up Time
Io = Full Load, Vin = 100VAC
0.3
1
2
OUTPUT (Vo)
Output Voltage Range
See Rating Chart
Load Regulation
Vin = 230VAC
3
5
Line Regulation
Io = Full Load
0.5
1
Output Power Range
Vin = 90 to 264VAC
0
63
Output Current Range
See Rating Chart
Ripple & Noise (peak to peak)
Full Load, Vin = 90VAC
0.5
1
Transient Response
Io = Full Load to Half Load, Vin = 100VAC
4
Hold-Up Time
Io = Full Load, Vin = 110VAC
16
PROTECTION
Over Voltage Protection
112
132
Over Current Protection
102
150
GENERAL
Efficiency
Io = Full Load, Vin = 230VAC
84
88
91
Dielectric Withstanding Voltage
For Primary to Secondary
Primary to Secondary
4242
Dielectric Withstanding Voltage
For Primary to Ground
Primary to Ground
2121
Isolation Resistance
Test Voltage = 500VDC
50
Power Consumption (No Load)
No Load, Vin = 240VAC
0.1
0.5
ENVIRONMENTAL
Operating Temperature
Derate linearly from 100% Load at 40°C to 50% load at 70°C
0
70
Storage Temperature
-40
85
Relative Humidity
5
95
Temperature Coefficient
All Outputs
-0.04
+0.04
MTBF
Operating Temp. at 25°C, Calculated per MIL-HDBK-217F
130,000
PHYSICAL
Weight
Approximately 340g
Dimensions
4.65 x 2.05 x 1.36
Warranty
2
SAFETY
CISPR
Vin = 220VAC
B
FCC
Vin = 110VAC
B
Safety Standards
UL/CUL, TUV-GS, CE, CB, PSE
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
Unit
VAC
Hz
A
A
A
A
mA
s
VDC
%
%
W
A
%
ms
ms
%
%
%
VDC
VDC
MΩ
W
°C
°C
%
%/°C
hours
grams
inches
years
Class
Class