English
Language : 

DTIPU30 Datasheet, PDF (1/2 Pages) Wall Industries,Inc. – Single Output Up to 30 Watts AC/DC Desktop Power Supply
Rev A
DTIPU30 Series
Single Output
Up to 30 Watts
AC/DC Desktop Power Supply
FEATURES
APPLICATIONS
● Splash Proof
● Scanners
● 100% Burn-in
● LCD Monitors
● Class I Insulation
● Thermal Printers
● IEC-320-C14 Input Inlet
● Humidity Temperature Meters
● Optional Output Connectors Available
● Over Voltage Protection (Crowbar Design)
● -20°C ~ +70°C Operating Temperature Range
● Wide Input Voltage Range: 90 to 264VAC, 47~63Hz
● Input Surge Current, Over Voltage, and Over Load Protection
DESCRIPTION
The DTIPU30 series of AC/DC desktop switching mode power supplies provide up to 30 watts of continuous output power. All models have
a single output, universal input voltage range, and an operating temperature range of –20°C ~ +70°C. These supplies are also protected
against input surge current, over voltage, and over load conditions. All supplies are also UL 94V-1 compliant and include an IEC-320-C14
input connector for worldwide applications. All models meet FCC-Part-15 class B and CISPR-22 class B emission limits and are designed
to comply with UL/c-UL (UL 60950-1), TUV/GS (EN 60950-1), and new CE requirements. These supplies are 100% burn-in tested.
SPECIFICATIONS: DTIPU30 Series
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
INPUT (Vin)
Operating Voltage Range
Input Frequency
Input Current (Low Line)
Input Current (High Line)
Inrush Current (Low Line)
Inrush Current (High Line)
Safety Ground Leakage Current
Start-Up Time
OUTPUT (Vo)
Output Voltage
Load Regulation
Line Regulation
Output Power
Output Current
*Ripple & Noise (peak to peak)
Transient Response Time
Hold-Up Time
Temperature Coefficient
PROTECTION
Over Voltage Protection
Over Current Protection
GENERAL
Efficiency
Dielectric Withstanding Voltage
For Primary to Secondary
Dielectric Withstanding Voltage
For Primary to Ground
Isolation Resistance
ENVIRONMENTAL
Operating Temperature
Storage Temperature
Relative Humidity
MTBF
PHYSICAL
Weight
Dimensions (L x W x H)
Warranty
SAFETY
EMI Requirements for CISPR-22
EMI Requirements for FCC PART-15
TEST CONDITIONS
Io = Full Load, Vin = 115VAC
Io = Full Load, Vin = 230VAC
Io = Full Load, 25°C, Cool Start, Vin = 115VAC
Io = Full Load, 25°C, Cool Start, Vin = 230VAC
Io = Full Load, Vin = 240VAC
Io = Full Load, Vin = 100VAC
Vin = 230VAC
Io = Full Load
Vin = 90 to 264VAC
Full Load, Vin = 90VAC
Io = Full Load to Half Load, Vin = 100VAC
Io = Full Load, Vin = 100VAC
All Outputs
Io = Full Load, Vin = 230VAC
Primary to Secondary
Primary to Ground
Test Voltage = 500VDC
Derates linearly from 100% Load at 40°C to 50% load at 70°C
Operating Temperature at 25°C, Calculated per MIL-HDBK-217F
Vin = 220VAC
Vin = 110VAC
Min Nom Max Unit
90
264
VAC
47
63
Hz
0.8
A
0.5
A
12
15
A
26
30
A
0.5
0.75
mA
0.3
1
2
s
See Rating Chart
3
7
0.5
1
0
30
See Rating Chart
0.5
1
4
12
-0.04
+0.04
VDC
%
%
W
A
%
ms
ms
%/°C
112
132
%
110
150
%
65
75
4242
85
%
VDC
2121
50
VDC
MΩ
-20
+70
°C
-40
+85
°C
5
95
%
100,000 hours
Approximately 265 ~ 280 grams
4.65 x 2.05 x 1.36 inches
118.0 x 52.0 x 34.5 mm
2 years
B
Class
B
Class
*Note: The Ripple & Noise for output voltages under 3.3VDC is 2% max.