English
Language : 

DTIPU25 Datasheet, PDF (1/3 Pages) Wall Industries,Inc. – 25 Watt Single Output AC/DC Desktop Power Supply
Rev A
DTIPU25 Series
25 Watt
Single Output
AC/DC Desktop Power Supply
FEATURES
● Splash Proof
● 2 Year Warranty
● B Type: Class II Insulation
● Optional Output Connectors
● A & C Types: Class I Insulation
● 3 Types of Inlet Connectors Available
● Approved as Limited Power Source (LPS)
● Wide Input Voltage 90~264VAC, 47~63Hz
● -20°C~+70°C Operating Temperature Range
Type A
Type B
Type C
DESCRIPTION
The DTIPU25 Series of AC/DC switching mode single output power supplies provides 25 watts of continuous output power. All models have a
single output, universal input voltage range, and an operating temperature range of -20°C ~ +70°C. This series also has three types of AC inlet
connectors to choose from: Type A (IEC-320-C14), Type B (IEC-320-C8), or Type C (IEC-320-C6). All supplies are UL 94V-1 compliant. All models
meet FCC Part-15 class B and CISPR-22 class B emission limits and are designed to comply with UL/cUL (UL 60950-1), TUV/GS (EN 60950-1)
and new CE requirements. All units are Energy Star compliant and 100% burn-in tested.
SPECIFICATIONS: DTIPU25 Series
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
Min Nom Max
Unit
INPUT (Vin)
Operating Voltage Range
90
264
VAC
Input Frequency
47
63
Hz
Input Current (Low Line)
Io = Full Load, Vin = 115VAC
0.4
A
Input Current (High Line)
Io = Full Load, Vin = 230VAC
0.25
A
Inrush Current (Low Line)
Io = Full Load, 25°C, Cool Start, Vin = 115VAC
12
15
A
Inrush Current (High Line)
Io = Full Load, 25°C, Cool Start, Vin = 230VAC
26
30
A
Safety Ground Leakage Current
(A & C Types Only)
Io = Full Load, Vin = 240VAC
0.5
0.75
mA
Safety Ground Leakage Current
(B Type Only)
Io = Full Load, Vin = 240VAC
0.15
0.25
mA
Start-Up Time
Io = Full Load, Vin = 100VAC
0.25
0.5
s
OUTPUT (Vo)
Output Voltage Range
See Rating Chart
Load Regulation
Vin = 230VAC
1
3
5
%
Line Regulation
Io = Full Load
0.5
1
%
Output Power Range
Vin = 90 to 264VAC
0
25
W
Output Current Range
See Rating Chart
Ripple & Noise (peak to peak)
Full Load, Vin = 90VAC
0.5
1
%
Transient Response Time
Io = Full Load to Half Load, Vin = 100VAC
4
ms
Hold-Up Time
Io = Full Load, Vin = 110VAC
12
14
16
ms
PROTECTION
Over Voltage Protection
Nil
%
Over Current Protection
110
150
%
GENERAL
Efficiency
Io = Full Load, Vin = 230VAC
75
85
95
%
Dielectric Withstanding Voltage
For Primary to Secondary
Primary to Secondary
4242
VDC
Dielectric Withstanding Voltage
For Primary to Ground (A & C Types Only)
Primary to Ground
2121
VDC
Isolation Resistance
Test Voltage = 500VDC
50
MΩ
No Load Power Consumption
No Load, Vin = 240VAC
0
0.4
0.5
W
ENVIRONMENTAL
Operating Temperature
Derate linearly from 100% Load at 40°C to 50% load at 70°C
-20
70
°C
Storage Temperature
-40
85
°C
Relative Humidity
5
95
%
Temperature Coefficient
All Outputs
-0.04
+0.04
%/°C
MTBF
300,000 hours
PHYSICAL
Weight
Approximately 170 grams
Dimensions
A Type: 4.11 x 1.65 x 1.22 inches
B & C Types: 3.90 x 1.65 x 1.22 inches
Input Inlet
IEC-320-C14, IEC-320-C8, IEC-320-C6
Warranty
2 years
SAFETY
CISPR (EMI Requirements for CISPR-22)
Vin = 220VAC
B
Class
FCC (EMI Requirements for FCC Part-15)
Vin = 110VAC
B
Class
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833