English
Language : 

P24X-24-24 Datasheet, PDF (1/1 Pages) Wabash Transformer Inc. – Split Bobbin Isolation Transformer
Split Bobbin Isolation Transformer
Series: P24X - Printed Circuit Mount, Horizontal 12 Pins
 Power Rating 2.4VA to 30VA
 Single Primary, 24V
 Frequency 50/60HZ
 Series or Parallel Secondary
 Dielectric Strength – 1500 Vrms
 Insulation Class B (130°C)
Agency Approvals:
 UL/cUL 5085-2 Recognized (File E47299)
 Insulation File No. E95662
Single Primary
● Indicates Like Polarity
Primaries and Secondaries are designed to be used
simultaneously. That is, they must be used either series or parallel
connected (as one winding). Same applies to secondaries also.
VA
Part
Rating Number
Secondary
Series
Parallel
L
2.4 P24X-24-24 24VCT @ 100mA 12V @ 0.200A 1.38
Dimensions (Inches)
W
H
A
B
C
1.12 1.13 0.15 0.20 0.86
20 P24X-20-24 24VCT @ 833mA 12V @ 1.670A 2.25 1.87 1.41 0.20 0.30 1.30
30 P24X-30-24 24VCT @ 1.250A 12V @ 2.500A 2.25 1.87 1.79 0.20 0.30 1.30
D
0.172
Mounting Dimension
K
MN
P
-
1.00
-
-
0.140 0.219 X 0.09* 1.69 1.50 1.88
0.140 0.219 X 0.09* 1.69 1.50 1.88
* = Slots
Wgt.
lbs
0.230
0.780
1.150
Any application, Any requirement, Contact us for our Custom Designs
Sales Office:
50
300 W Factory Road, Addison IL 60101 • Phone: (630) 628-9999 • Fax: (630) 628-9922 • www.wabashtransformer.com