English
Language : 

STUA61 Datasheet, PDF (2/2 Pages) Vitec Power – 63W U-Bracket Power Supply for I.T. Equipment
STUA61-Q04-1
STUA61-Q04-2
STUA61-Q04-3
STUA61-Q23
+5V 0.6A
6A
+5V 0.6A
6A
+5V 0.6A
6A
+5V 0.1A
1A
5%
+15V 0.3A
3A
5%
-15V
0A
0.8A
5%
+5V
0A
5%
+15V 0.3A
3A
5%
+15V
0A
0.8A
5%
-5V
0A
5%
+15V 0.3A
3A
5%
+15V
0A
0.8A
5%
+5V
0A
5%
+24V 0.18A 1.8A
5%
-15V
0A
0.1A
5%
+12V
0A
Electrical Characteristics
Parameter
Test Conditions
Min.
Typ.
Input Voltage
Operating Voltage
90
Input Frequency
47
Output Power Range
Vin=90 to 264VAC
0
Input Current (Low Line)
Io=Full load, Vin=115VAC
Input Current (High Line)
Io=Full load, Vin=230VAC
Low Line Inrush Current
Io=Full load, 25°C, Cool start,
Vin=115VAC
12
High Line Inrush Current
Efficiency
Io=Full load, 25°C, Cool start,
Vin=230VAC
Io=Full Load, Vin=230VAC
26
70
80
Line Regulation
Io=Full Load
0.5
Load Regulation
Vin=230VAC
3
Over Voltage Protection
112
Over Current Protection
110
Transient Response
Io=Full Load to Half Load, Vin=100VAC
Hold-Up Time
Io=Full Load, Vin=110VAC
12
Start Up Time
* Ripple & Noise (Peak to Peak)
Io=Full Load, Vin=100VAC
Full Load, Vin=90VAC
0.3
1
0.5
Safety Ground Leakage Current
Temperature Coefficient
Io=Full Load, Vin=240VAC
All output
0.4
-0.04
* Note: The Ripple & Noise which is under 3.3VDC at 2% max
The range of OCP is set between 110-150% of total output power .
Conditions
Parameter
Test Conditions
Operating Temperature
Storage Temperature
Relative Humidity
Operating Temperature at 25°C, Calculated per MIL-HDBK-217F
De-rate linearly from 100% load at 25°C to 50% load at 70°C
Min.
Typ.
0
25
-40
5
0.1M
Approvals and Compliance
Parameter
Dielectric Withstanding Voltage for Primary to secondary
Dielectric Withstanding Voltage for Primary to Ground
Isolation Resistance
EMI requirements for CISPR-22
EMI requirements for FCC PART-15
Test Conditions
Primary to secondary
Primary to ground
Test Voltage=500VDC
Vin=220VAC
Vin=110VAC
Mechanical
PIN CHART
PIN
MODEL
1
2
3
4
5
6
7
8
STUA61-SXX OUT OUT OUT RTN RTN RTN
STUA61-DXX Vo2 Vo1 Vo1 COM COM N/C
STUA61-D15 N/C Vo1 Vo1 COM COM Vo3
STUA61-TXX Vo2 Vo1 Vo1 COM COM Vo3
STUA61-QXX Vo2 Vo1 Vo1 COM COM Vo3 Vo4 Vo4
Note: Vo1: Output#1 Vo2: Output#2 Vo3: Output#3 Vo4:Output#4
Note:
1. Dimensions are shown in inches or mm.
2. Weight: 250gs approx.
3. Input connector mates with Molex housing 09-50-3031 and
Molex 2478 series crimp terminal.
4. Output connector mates with Molex housing 09-50-3061 (or
09-50-3081) and Molex 2478 series crimp terminal
0.8A
5%
0.8A
5%
0.8A
5%
0.8A
5%
Max.
264
63
63
1.6
1.0
15
30
88
1
7
132
150
4
2
1
0.75
0.04
Max.
70
85
95
Min.
4242
2121
50
B
B
63W
63W
63W
59. 3W
Unit
VAC
Hz
W
A
A
A
A
%
%
%
%
%
mS
mS
S
%
mA
%/°C
Unit
°C
°C
%
Hrs
Unit
VDC
VDC
MΩ
CLASS
CLASS