SMDA15A SERIES
15W Desktop Power Supply For Medical Equipment
– Wide Input Voltage 90 to 264 VAC, 47 to 63Hz
– IEC-320-C14 input inlet
– Single Output
– Output Voltage Available From 5VDC Thru 36VDC
– Over Voltage, Over Load, and Over Temperature Protection
– Class I Insulation
– Energy Star 2.0, CEC Level V, and RoHS Compliance
3 Year Warranty
Approvals:
Single Output
Part Number
Output Voltage
Max. Output Current
SMDA15A-S02
5 ~ 6 VDC
2.60 ~ 2.16 A
SMDA15A-S03
6 ~ 8 VDC
2.16 ~ 1.62 A
SMDA15A-S04
8 ~ 11 VDC
1.87 ~ 1.36 A
SMDA15A-S05
11 ~ 13 VDC
1.36 ~ 1.15 A
SMDA15A-S06
13 ~ 16 VDC
1.15 ~ 0.93 A
SMDA15A-S07
16 ~ 21 VDC
0.93 ~ 0.71 A
SMDA15A-S08
21 ~ 27 VDC
0.71 ~ 0.55 A
SMDA15A-S09
27 ~ 33 VDC
0.55 ~ 0.45 A
SMDA15A-S10
33 ~ 36 VDC
0.45 ~ 0.41 A
The total regulation on model S02, S03, S05 is required to use AWG#16 / 4FT output cable.
The total regulation on model S04, S06~S10 is required to use AWG#18 / 4FT output cable.
The regulation and efficiency are not guaranteed if changes the output cable
Total Regulation
5%
5%
5%
5%
5%
5%
3%
3%
3%
Electrical Characteristics
Parameter
Test Conditions
Input Voltage
Operating Voltage
Input Frequency
Output Power Range
Vin=90 to 264VAC
Input Current (Low Line)
Io=Full load, Vin=115VAC
Input Current (High Line)
Io=Full load, Vin=230VAC
Low Line Inrush Current
Io=Full load, 25°C Cool start, Vin=115VAC
High Line Inrush Current
Io=Full load, 25°C Cool start, Vin=230VAC
Efficiency
Io=Full Load, Vin=230VAC
Line Regulation
Io=Full Load
Load Regulation
Vin=230VAC
Over Voltage Protection*
Over Current Protection*
Transient Response
Io=Full Load to Half Load, Vin=100VAC
Hold-Up Time
Io=Full Load, Vin=110VAC
Start Up Time
Io=Full Load, Vin=100VAC
Ripple & Noise(Peak to Peak)
Full Load, Vin=90VAC
Safety Ground Leakage Current
Io=Full Load, Vin=240VAC
Temperature Coefficient
All output
No-Load Power Consumption
No load, Vin=240VAC
Thermal Shutdown By Junction
The parameter is not subject to production
Temperature Controller *
test-verified by design/characterization of integrated
controller. Auto recovery.
*When the power system interruption is isolated, the product would re-start after recovering by hand.
Min.
90
47
0
73
1
112
110
10
0.3
-0.04
-20
Typ.
0.25
0.17
14
28
0.5
3
16
1
0.5
0.25
Max. Output Power
13W
13W
15W
15W
15W
15W
15W
15W
15W
Max.
Unit
264
VAC
63
Hz
15
W
0.33
A
0.18
A
16
A
30
A
85
%
1
%
5
%
132
%
150
%
4
mS
mS
2
S
1
%
0.3
mA
0.04
%/°C
0.3
W
125
°C