ILPA75VW SERIES
75W Water-Proof Constant Voltage LED Driver
– Wide Input Voltage 90 to 264VAC, 47 to 63Hz
– Constant Output Voltage Available From 12VDC Thru 105VDC
– Over Voltage, Over Current, Short Circuit, Lighting, and Over Temperature Protection
– High Efficiency (up to 93%)
– Active Power Factor Correction (PFC) (99% typical)
– IP67 Waterproof Rating, Metal Housing
– Comply with UL8750 & EN61347 Safety Regulation (Pending)
3 Year Warranty
Approvals:
Part Number
ILPA75VW-S012ST
ILPA75VW-S024ST
ILPA75VW-S036ST
ILPA75VW-S042ST
ILPA75VW-S048ST
ILPA75VW-S054ST
ILPA75VW-S081ST
ILPA75VW-S105ST
Parameter
Input Voltage
Input Frequency
Output Power Range
Input Current (Low Line)
Input Current (High Line)
High Line Inrush Current
Power Factor Correction
Power Factor Correction
Efficiency
No-Load Power Consumption
Line Regulation
Load Regulation
Over Voltage Protection
Over Current Protection
Over Temperature Protection
Short Circuit Protection
Output Overshoot / Undershoot
Start Up Time
Ripple & Noise (Peak to Peak)
Output Voltage
12 VDC
24 VDC
36 VDC
42 VDC
48 VDC
54 VDC
81 VDC
105 VDC
Single Output
Max.
Efficiency
Output Current
6.25 A
3.13 A
2.08 A
1.79 A
1.56 A
1.39 A
0.93 A
0.71 A
(220VAC, Full Load)
91%
92%
92%
92%
92%
93%
93%
93%
Over Voltage
Protection
16V
33V
45V
50V
58V
63V
90V
120V
Max.
Output Power
75W
75W
75W
75W
75W
75W
75W
75W
Electrical Characteristics
Test Conditions
Min.
Typ.
Max.
Unit
Operating Voltage
90
264
VAC
47
63
Hz
Vin=90 to 264VAC
0
75
W
Io=Full load, Vin=115VAC
0.9
A
Io=Full load, Vin=230VAC
0.45
A
Io=Full load, 25°C, Cool start, Vin=230VAC
50
A
Vin=110VAC
99
%
Vin=220VAC
95
%
Io=Full Load, Vin=230VAC
93
%
No Load, VIn=230VAC
1.5
W
Io=Full Load
1
%
Vin=230VAC
2
%
Latch mode. The power unit shall return to normal operation only after the power is turn-on again.
(Please refer to output table.)
135
% Io
110
°C
No damage shall occur when any output operating in a short circuit condition. The power supply shall be
self-recovery when the fault condition is removed.
When power on or off
10
%
Io=Full Load, Vin=100VAC
3
S
Measured by 20 MHz bandwidth oscilloscope and the
output paralleled a 0.1 uF ceramic capacitor and a 10
2
% Vo
uF electrolytic capacitor.