English
Language : 

ILPA75JU-SERIES Datasheet, PDF (1/2 Pages) Vitec Power – 75W Water-Proof Constant Current LED Driver
ILPA75JU SERIES
2 Year Warranty
75W Water-Proof Constant Current LED Driver
– Wide Input Voltage 90 to 305VAC, 47 to 63Hz
– Constant Output Current Available From 350mA To 5000mA
– Over Voltage, Short Circuit, Lighting, and Over Temperature Protection
– High Efficiency (up to 92%)
– Active Power Factor Correction (PFC) (99% typical)
– IP67 Waterproof Rating, Metal Housing
– Comply with UL8750 & EN61347 Safety Regulation
Approvals:
Part Number
ILPA75JU-S500ST
ILPA75JU-S210ST
ILPA75JU-S280ST
ILPA75JU-S3750ST
ILPA75JU-S140ST
ILPA75JU-S105ST
ILPA75JU-S070ST
ILPA75JU-S045ST
ILPA75JU-S035ST
Output Current Range
(Min. / Typ. / Max.)
4750 / 5000 / 5250mA
3565 / 3750 / 3935mA
2660 / 2800 / 2940mA
1995 / 2100 / 2205mA
1330 / 1400 / 1470mA
1000 / 1050 / 1100mA
665 / 700 / 735mA
428 / 450 / 472mA
332 / 350 / 368mA
Single Output
Output Voltage
(Min. / Max.)
7 / 15 VDC
10 / 20 VDC
13 / 27 VDC
18 / 36 VDC
27 / 54 VDC
36 / 72 VDC
54 / 108 VDC
83 / 166 VDC
107 / 214 VDC
Efficiency
(220VAC, Full Load)
88%
88%
89%
89%
90%
90%
91%
92%
92%
Over Voltage Protection
(Typ. / Max.)
18 / 25 VDC
26 / 30 VDC
35 / 38 VDC
42 / 45 VDC
65 / 70 VDC
80 / 88 VDC
118 / 130 VDC
195 / 215 VDC
235 / 250 VDC
Max.
Output Power
75W
75W
75W
75W
75W
75W
75W
75W
75W
Parameter
Input Voltage
Input Frequency
Output Power Range
Input Current (Low Line)
Input Current (High Line)
High Line Inrush Current
Power Factor Correction
Efficiency
Line Regulation
Load Regulation
Over Voltage Protection
Over Temperature Protection
Short Circuit Protection
Output Overshoot / Undershoot
Start Up Time
Ripple & Noise (Peak to Peak)
Electrical Characteristics
Test Conditions
Min.
Typ.
Max.
Unit
Operating Voltage
90
305
VAC
47
63
Hz
Vin=90 to 305VAC
0
75
W
Io=Full load, Vin=115VAC
0.90
A
Io=Full load, Vin=230VAC
0.40
A
Io=Full load, 25°C, Cool start, Vin=230VAC
50
A
Vin=110VAC
96
99
%
Io=Full Load, Vin=220VAC
88
92
%
Io=Full Load
1
%
Vin=230VAC
3
%
Latch mode. The power unit shall return to normal operation only after the power is turn-on again.
(Please refer to output table.)
110
°C
No damage shall occur when any output operating in a short circuit condition. The power supply shall be
self-recovery when the fault condition is removed.
When power on or off
10
%
Io=Full Load, Vin=100VAC
0.6
S
Measured by 20 MHz bandwidth oscilloscope and the
output paralleled a 0.1 uF ceramic capacitor and a 10
uF electrolytic capacitor.
5
% Vo
Conditions
Parameter
Test Conditions
Operating Temperature
Humidity: 10% RH to 100% RH
Storage Temperature
Humidity: 5% RH to 100% RH
MTBF: Operation temperature at 25°C, calculated per MIL-HDBK-217F
Life Time at 25°C ambient temperature
Min.
Typ.
-35
-40
0.498M
0.065M
Max.
70
85
Unit
°C
°C
Hours