English
Language : 

ILPA60JU-SERIES Datasheet, PDF (1/2 Pages) Vitec Power – 60W Water-Proof Constant Current LED Driver
ILPA60JU SERIES
2 Year Warranty
60W Water-Proof Constant Current LED Driver
– Wide Input Voltage 90 to 305VAC, 47 to 63Hz
– Constant Output Current Available From 350mA To 5000mA
– Over Voltage, Short Circuit, Lighting, and Over Temperature Protection
– High Efficiency (up to 91%)
– Active Power Factor Correction (PFC) (99% typical)
– IP67 Waterproof Rating, Metal Housing
– Comply with UL8750 & EN61347 Safety Regulation
Approvals:
Part Number
ILPA60JU-S500ST
ILPA60JU-S330ST
ILPA60JU-S230ST
ILPA60JU-S170ST
ILPA60JU-S140ST
ILPA60JU-S105ST
ILPA60JU-S070ST
ILPA60JU-S045ST
ILPA60JU-S035ST
Output Current Range
(Min. / Typ. / Max.)
4750 / 5000 / 5250mA
3135 / 3300 / 3465mA
2185 / 2300 / 2415mA
1615 / 1700 / 1785mA
1330 / 1400 / 1470mA
1000 / 1050 / 1100mA
665 / 700 / 735mA
428 / 450 / 472mA
332 / 350 / 368mA
Single Output
Output Voltage
(Min. / Max.)
6 / 12 VDC
9 / 18 VDC
13 / 27 VDC
18 / 36 VDC
21 / 43 VDC
29 / 58 VDC
43 / 86 VDC
67 / 134 VDC
85 / 170 VDC
Efficiency
(220VAC, Full Load)
87%
88%
89%
90%
90%
90%
91%
91%
91%
Over Voltage Protection
(Typ/Max)
15 / 17VDC
23 / 25VDC
35 / 38VDC
42 / 45VDC
50 / 55VDC
65 / 70VDC
92 / 102VDC
145 / 160VDC
195 / 215VDC
Max.
Output Power
60W
60W
60W
60W
60W
60W
60W
60W
60W
Parameter
Input Voltage
Input Frequency
Output Power Range
Input Current (Low Line)
Input Current (High Line)
High Line Inrush Current
Power Factor Correction
Efficiency
Line Regulation
Load Regulation
Over Voltage Protection
Over Temperature Protection
Short Circuit Protection
Output Overshoot / Undershoot
Start Up Time
Ripple & Noise (Peak to Peak)
Electrical Characteristics
Test Conditions
Min.
Typ.
Max.
Unit
Operating Voltage
90
305
VAC
47
63
Hz
Vin=90 to 305VAC
0
60
W
Io=Full load, Vin=115VAC
0.80
A
Io=Full load, Vin=230VAC
0.36
A
Io=Full load, 25°C, Cool start, Vin=230VAC
50
A
Vin=110VAC
95
99
%
Io=Full Load, Vin=220VAC
87
91
%
Io=Full Load
1
%
Vin=230VAC
3
%
Latch mode. The power unit shall return to normal operation only after the power is turn-on again.
(Please refer to output table.)
110
°C
No damage shall occur when any output operating in a short circuit condition. The power supply shall be
self-recovery when the fault condition is removed.
When power on or off
10
%
Io=Full Load, Vin=100VAC
0.6
S
Measured by 20 MHz bandwidth oscilloscope and the
output paralleled a 0.1 uF ceramic capacitor and a 10
uF electrolytic capacitor.
5
% Vo
Conditions
Parameter
Operating Temperature
Test Conditions
Humidity: 10% RH to 100% RH
Storage Temperature
Humidity: 5% RH to 100% RH
MTBF: Operation temperature at 25°C, calculated per MIL-HDBK-217F
Life Time at 25°C ambient temperature
Min.
Typ.
-35
-40
0.546M
0.080M
Max.
70
85
Unit
°C
°C
Hours
Hours