ILPA50JW SERIES
50W Water-Proof Constant Current LED Driver
– Wide Input Voltage 90 to 264VAC, 47 to 63Hz
– Constant Output Current Available From 0.35A To 3.0A
– Over Voltage, Short Circuit, Lighting, and Over Temperature Protection
– High Efficiency (up to 88%)
– Active Power Factor Correction (PFC) (87% typical)
– IP67 Waterproof Rating, Metal Housing
– Comply with UL8750 & EN61347 Safety Regulation
2 Year Warranty
Approvals:
Single Output
Part Number
Output Current Range Output Voltage Range
(Min. / Typ. / Max.)
(Min. / Max.)
Efficiency
Over Voltage Protection
(220VAC, Full Load)
(Min/Typ/Max)
ILPA50JW-S300SS 2850 / 3000 / 3150 mA
7 / 12 VDC
84%
14 / 16 / 18 VDC
ILPA50JW-S277SS 2635 / 2770 / 2905 mA
9 / 18 VDC
85%
22 / 24 / 27 VDC
ILPA50JW-S210SS 1995 / 2100 / 2205 mA
13 / 24 VDC
86%
29 / 32 / 36 VDC
ILPA50JW-S140SS 1330 / 1400 / 1470 mA
18 / 36 VDC
87%
43 / 48 / 54 VDC
ILPA50JW-S119SS 1130 / 1100 / 1250 mA
21 / 45.5 VDC
87%
50 / 57 / 63 VDC
ILPA50JW-S105SS 997 / 1050 / 1102 mA
24 / 48 VDC
88%
58 / 65 / 72 VDC
ILPA50JW-S070SS
665 / 700 / 735 mA
36 / 72 VDC
88%
86 / 97 / 108 VDC
ILPA50JW-S045SS
428 / 450 / 472 mA
56 / 111 VDC
88%
133 / 150 / 167 VDC
ILPA50JW-S035SS
333 / 350 / 367 mA
71 / 142 VDC
88%
170 / 192 / 213 VDC
Item S300SS, -S277SS, -S210SS use Class 2 output (USR & CNR). Item -S119SS uses Class2 output (USR), Non-Class 2 output (CNR).
Item -S140SS, -S105SS, -S070SS,-S045SS,-S035SS use Non-Class 2 output (USR & CNR)
Max.
Output Power
50W
50W
50W
50W
50W
50W
50W
50W
50W
Parameter
Input Voltage
Input Frequency
Output Power Range
Input Current (Low Line)
Input Current (High Line)
High Line Inrush Current
Power Factor Correction
Efficiency
No-Load Power Consumption
Line Regulation
Load Regulation
Over Voltage Protection
Over Temperature Protection
Short Circuit Protection
Output Overshoot / Undershoot
Start Up Time
Ripple & Noise (Peak to Peak)
Electrical Characteristics
Test Conditions
Min.
Typ.
Max.
Unit
Operating Voltage
90
264
VAC
47
63
Hz
Vin=90 to 264VAC
0
50
W
Io=Full load, Vin=115VAC
0.70
A
Io=Full load, Vin=230VAC
0.35
A
Io=Full load, 25°C, Cool start, Vin=230VAC
65
A
Vin=110VAC
86
87
%
Io=Full Load, Vin=220VAC
84
88
%
No Load, VIn=230VAC
1
W
Io=Full Load
1
%
Vin=230VAC
3
%
Latch mode. The power unit shall return to normal operation only after the power is turn-on again.
(Please refer to output table.)
110
°C
No damage shall occur when any output operating in a short circuit condition. The power supply shall be
self-recovery when the fault condition is removed.
When power on or off
10
%
Io=Full Load, Vin=100VAC
3
S
Measured by 20 MHz bandwidth oscilloscope and
the output paralleled a 0.1 uF ceramic capacitor and
a 10 uF electrolytic capacitor.
2
% Vo