English
Language : 

ILPA40JUD-SERIES Datasheet, PDF (1/2 Pages) Vitec Power – 40W Dimmable Water-Proof Constant Current LED Driver
ILPA40JUD SERIES
2 Year Warranty
40W Dimmable Water-Proof Constant Current LED Driver
– Wide Input Voltage 90 to 305VAC, 47 to 63Hz
– Constant Output Current Available From 350mA To 3330mA
– Over Voltage, Short Circuit, Over Load Protection
– High Efficiency (up to 88%)
– Active Power Factor Correction (PFC) (92% typical)
– IP66 Waterproof Rating
– Comply with UL8750 & EN61347 Safety Regulation (Pending)
Approvals: (Pending)
Part Number
ILPA40JUD-S333DS
ILPA40JUD-S222DS
ILPA40JUD-S166DS
ILPA40JUD-S140DS
ILPA40JUD-S128DS
ILPA40JUD-S105DS
ILPA40JUD-S070DS
ILPA40JUD-S045DS
ILPA40JUD-S035DS
Output Current Range
(Min. / Typ. / Max.)
3164 / 3330 / 3497 mA
2109 / 2220 / 2331 mA
1577 / 1660 / 1743 mA
1330 / 1400 / 1470 mA
1216 / 1280 / 1344 mA
998 / 1050 / 1103 mA
665 / 700 / 735 mA
428 / 450 / 473 mA
333 / 350 / 368 mA
Single Output
Output Voltage
(Min. / Max.)
4 / 12 VDC
6 / 18 VDC
8 / 24 VDC
10 / 29 VDC
11 / 31 VDC
12 / 36 VDC
18 / 54 VDC
30 / 89 VDC
38 / 114 VDC
Efficiency
(220VAC, Full Load)
84%
85%
86%
87%
87%
87%
87%
88%
88%
Over Voltage Protection
(Min. / Typ. / Max.)
13 / 15 / 17 VDC
22 / 24 / 26 VDC
30 / 32 / 34 VDC
36 / 38 / 40 VDC
41 / 43 / 45 VDC
46 / 48 / 50 VDC
68 / 70 / 72 VDC
114 / 116 / 118 VDC
146 / 148 / 150 VDC
Max.
Output Power
35W
36W
38W
36W
38W
38W
38W
40W
40W
Parameter
Input Voltage
Input Frequency
Output Power Range
Input Current (Low Line)
Input Current (High Line)
High Line Inrush Current
Power Factor Correction
Efficiency
No Load Power Dissipation
Line Regulation
Load Regulation
Over Voltage Protection
Over Load Protection
Short Circuit Protection
Output Overshoot / Undershoot
Start Up Time
Ripple & Noise (Peak to Peak)
Electrical Characteristics
Test Conditions
Operating Voltage
Vin=90 to 305VAC
Io=Full load, Vin=115VAC
Io=Full load, Vin=230VAC
Io=Full load, 25°C, Cool start, Vin=230VAC
Min.
Typ.
Max.
Unit
90
305
VAC
47
63
Hz
0
40
W
0.48
A
0.23
A
20
A
Vin=110VAC
99
%
Io=Full Load, Vin=220VAC
88
%
3
W
Io=Full Load
2
%
Vin=230VAC
5
%
Latch mode. The power unit shall return to normal operation only after the power is turn-on again.
(Please refer to output table.)
Hiccup mode. The power supply shall be self-recovery
when the fault condition is removed.
1.25
Po
No damage shall occur when any output operating in a short circuit condition. The power supply shall be
self-recovery when the fault condition is removed.
When power on or off
10
%
Io=Full Load, Vin=100VAC
1.7
2
S
Measured by 20 MHz bandwidth oscilloscope and the
output paralleled a 0.1 uF ceramic capacitor and a 10
uF electrolytic capacitor.
5
% Vo