ILPA30VW SERIES
2 Year Warranty
30W Water-Proof Constant Voltage LED Driver
– Wide Input Voltage 90 to 264VAC, 47 to 63Hz
– Constant Output Voltage Available for 12VDC and 24VDC
– Over Voltage, Short Circuit, and Over Temperature Protection
– High Efficiency (up to 86%)
– Active Power Factor Correction (PFC) (86% typical)
– IP67 Waterproof Rating, Metal Housing
– Comply with UL8750 & EN61347 Safety Regulation (Pending)
Approvals:
Single Output
Part Number
Output Voltage
Max.
Output Current
ILPA30VW-S012SS
12 VDC
2.50 A
ILPA30VW-S024SS
24 VDC
1.25 A
Item -S012SS, -S024SS use Class 2 output (USR & CNR).
Efficiency
Over Voltage Protection
(220VAC, Full Load) Min / Typ / Max
83%
14V / 16V / 18V
83%
29V/ 33V / 36V
Max.
Output Power
30W
30W
Parameter
Input Voltage
Input Frequency
Output Power Range
Input Current (Low Line)
Input Current (High Line)
High Line Inrush Current
Power Factor Correction
Power Factor Correction
Efficiency
No-Load Power Consumption
Line Regulation
Load Regulation
Over Voltage Protection
Over Current Protection
Over Temperature Protection
Short Circuit Protection
Output Overshoot / Undershoot
Start Up Time
Ripple & Noise (Peak to Peak)
Electrical Characteristics
Test Conditions
Min.
Typ.
Max.
Unit
Operating Voltage
90
264
VAC
47
63
Hz
Vin=90 to 264VAC
0
30
W
Io=Full load, Vin=115VAC
0.43
A
Io=Full load, Vin=230VAC
0.25
A
Io=Full load, 25°C, Cool start, Vin=230VAC
65
A
Vin=110VAC
85
%
Vin=220VAC
83
%
Io=Full Load, Vin=230VAC
83
85
%
No Load, VIn=230VAC
1
W
Io=Full Load
1
%
Vin=230VAC
3
%
Latch mode. The power unit shall return to normal operation only after the power is turn-on again.
(Please refer to output table.)
120
130
170
% Io
110
°C
No damage shall occur when any output operating in a short circuit condition. The power supply shall be
self-recovery when the fault condition is removed.
When power on or off
10
%
Io=Full Load, Vin=100VAC
3
S
Measured by 20 MHz bandwidth oscilloscope and the
output paralleled a 0.1 uF ceramic capacitor and a 10
2
% Vo
uF electrolytic capacitor.
Conditions
Parameter
Test Conditions
Operating Temperature
Humidity: 10% RH to 100% RH
Storage Temperature
Humidity: 5% RH to 100% RH
Operation temperature at 25°C, calculated per MIL-HDBK-217F
Life Time at 25°C ambient temperature
Min.
Typ.
-35
-40
0.3M
0.08M
Max.
60
85
Unit
°C
°C
Hours
Hours