ILPA150VW-SERIES Datasheet, PDF (1/2 Pages) Vitec Power – 150W Water-Proof Constant Voltage LED Driver
ILPA150VW SERIES
150W Water-Proof Constant Voltage LED Driver
– Wide Input Voltage 90 to 264VAC, 47 to 63Hz
– Constant Output Voltage Available From 12VDC To 105VDC
– Over Voltage, Over Current, Short Circuit, and Over Temperature Protection
– High Efficiency (up to 94%)
– Active Power Factor Correction (PFC) (99% typical)
– IP67 Waterproof Rating, Metal Housing
– Comply with UL8750 & EN61347 Safety Regulation (Pending)
2 Year Warranty
Approvals:
Part Number
ILPA150VW-S012ST
ILPA150VW-S024ST
ILPA150VW-S036ST
ILPA150VW-S042ST
ILPA150VW-S048ST
ILPA150VW-S050ST
ILPA150VW-S052ST
ILPA150VW-S054ST
ILPA150VW-S056ST
ILPA150VW-S081ST
ILPA150VW-S105ST
Output Voltage
12 VDC
24 VDC
36 VDC
42 VDC
48 VDC
50 VDC
52VDC
54 VDC
56 VDC
81 VDC
105 VDC
Single Output
Max.
Efficiency
Output Current
12.5 A
6.25 A
4.17 A
3.75 A
3.57 A
3.13 A
3.00A
2.88 A
2.78 A
1.85 A
1.42 A
(220VAC, Full Load)
92%
93%
93%
94%
93%
93%
93%
93%
93%
94%
94%
Over Voltage Protection
Min / Typ / Max
14V / 15V / 16V
27V / 30V / 34V
40V / 43V / 48V
45V / 50V / 53V
47V / 51V / 55V
54V / 58V / 61V
56V / 60V / 63V
58V / 62V / 66V
60V / 65V / 69V
91V / 95V / 100V
118V / 128V / 135V
Max.
Output Power
150W
150W
150W
150W
150W
150W
150W
150W
150W
150W
150W
Parameter
Input Voltage
Input Frequency
Output Power Range
Input Current (Low Line)
Input Current (High Line)
High Line Inrush Current
Power Factor Correction
Power Factor Correction
Efficiency
No-Load Power Consumption
Line Regulation
Load Regulation
Over Voltage Protection
Over Current Protection
Over Temperature Protection
Short Circuit Protection
Output Overshoot / Undershoot
Start Up Time
Ripple & Noise (Peak to Peak)
Electrical Characteristics
Test Conditions
Min.
Typ.
Max.
Operating Voltage
90
264
47
63
Vin=90 to 264VAC
0
150
Io=Full load, Vin=115VAC
1.75
Io=Full load, Vin=230VAC
0.8
Io=Full load, 25°C, Cool start, Vin=230VAC
50
Vin=110VAC
99
Vin=220VAC
96
Io=Full Load, Vin=230VAC
93
94
No Load, VIn=230VAC
1.5
Io=Full Load
1
Vin=230VAC
2
Latch mode. The power unit shall return to normal operation only after the power is turn-on again.
110
135
180
110
No damage shall occur when any output operating in a short circuit condition. Self-recovery.
When power on or off
10
Io=Full Load, Vin=100VAC
3
Measured by 20 MHz bandwidth oscilloscope and the
output paralleled a 0.1 uF ceramic capacitor and a 10 uF
2
electrolytic capacitor.
Unit
VAC
Hz
W
A
A
A
%
%
%
W
%
%
% Io
°C
%
S
% Vo