English
Language : 

ILPA100VU-SERIES Datasheet, PDF (1/2 Pages) Vitec Power – 100W Water-Proof Constant Voltage LED Driver
ILPA100VU SERIES
100W Water-Proof Constant Voltage LED Driver
– Wide Input Voltage 90 to 305VAC, 47 to 63Hz
– Constant Output Voltage Available From 12VDC Thru 105VDC
– Over Voltage, Over Current, Short Circuit, Lighting, and Over Temperature Protection
– High Efficiency (up to 93%)
– Active Power Factor Correction (PFC) (99% typical)
– IP67 Waterproof Rating, Metal Housing
– Comply with UL8750 & EN61347 Safety Regulation (Pending)
3 Year Warranty
Approvals:
Part Number
ILPA100VU-S012ST
ILPA100VU-S024ST
ILPA100VU-S036ST
ILPA100VU-S042ST
ILPA100VU-S048ST
ILPA100VU-S054ST
ILPA100VU-S081ST
ILPA100VU-S105ST
Output Voltage
12 VDC
24 VDC
36 VDC
42 VDC
48 VDC
54 VDC
81 VDC
105 VDC
Single Output
Max.
Output Current
8.33 A
4.05A
2.75 A
2.25 A
1.95 A
1.75 A
1.23 A
0.95 A
Efficiency
(220VAC, Full Load)
91%
93%
93%
93%
92%
93%
93%
93%
Over Voltage Protection
Min / Typ / Max
14V / 15V / 16V
27V / 30V / 34V
40V / 47V / 50V
47V / 52V / 57V
54V / 59V / 63V
60V / 68V / 75V
91V / 95V / 100V
120V / 125V / 140V
Max.
Output Power
100W
100W
100W
100W
100W
100W
100W
100W
Parameter
Input Voltage
Input Frequency
Output Power Range
Input Current (Low Line)
Input Current (High Line)
High Line Inrush Current
Power Factor Correction
Power Factor Correction
Efficiency
No-Load Power Consumption
Line Regulation
Load Regulation
Over Voltage Protection
Over Current Protection
Over Temperature Protection
Short Circuit Protection
Output Overshoot / Undershoot
Start Up Time
Ripple & Noise (Peak to Peak)
Electrical Characteristics
Test Conditions
Min.
Typ.
Max.
Unit
Operating Voltage
90
305
VAC
47
63
Hz
Vin=90 to 264VAC
0
100
W
Io=Full load, Vin=115VAC
1.20
A
Io=Full load, Vin=230VAC
0.60
A
Io=Full load, 25°C, Cool start, Vin=230VAC
65
A
Vin=110VAC
99
%
Vin=220VAC
96
%
Io=Full Load, Vin=230VAC
93
%
No Load, VIn=230VAC
1.5
W
Io=Full Load
1
%
Vin=230VAC
2
%
Latch mode. The power unit shall return to normal operation only after the power is turn-on again.
(Please refer to output table.)
110
135
180
% Io
110
°C
No damage shall occur when any output operating in a short circuit condition. The power supply shall be
self-recovery when the fault condition is removed.
When power on or off
10
%
Io=Full Load, Vin=100VAC
3
S
Measured by 20 MHz bandwidth oscilloscope and the
output paralleled a 0.1 uF ceramic capacitor and a 10
2
% Vo
uF electrolytic capacitor.