English
Language : 

SPU65-101 Datasheet, PDF (1/2 Pages) Volgen Kaga Electronics Inc. – 80W Desk Top Switching Power Supplies For I.T.E.
SPU65 SERIES
80W Desk Top Switching Power Supplies For I.T.E.
Description:
The SPU65 series of AC/DC switching mode power
supplies provide 80 Watts of continuous output power.
All supplies are UL 94V-0 compliant, include IEC-320-C14
input for worldwide applications. All models meet FCC Part-
15 class B and CISPR-22 class B emission Limits and are
designed to comply with UL, C-UL, TUV and CE
requirements. All units are 100% burned in and tested.
Features:
Wide Input Voltage 90 to 264 VAC,47 to 63 Hz
IEC-320-C14 Input Inlet
Single to Quad Output
Output Voltage Available From 3 VDC Thru 48 VDC
Optional Output Connector (See appendix)
Input Surge Current, Over Voltage and Over Load protection
Splash proof
Class I Insulation
Safety Approvals :
Two Years Warranty
Electrical Characteristics:
Product Safety
CB
PS
E
Sym.
Parameter
Test Conditions
Min. Typ. Max. Unit
Vin Input Voltage
Fin Input Frequency
Wo Output Power Range
Vo Output Voltage Range
Io Output Current Range
Iil Input Current (Low Line)
Iih Input Current (High Line)
Irl Low Line Inrush Current
Irh High Line Inrush Current
Eff Efficiency
REG-i Line Regulation
Vin=90 to 264VAC
Io=Full load, Vin=115VAC
Io=Full load, Vin=230 VAC
Io=Full load, 25°c, Cool start,
Vin=115VAC
Io=Full load, 25°c, Cool start,
Vin=230VAC
Io=Full Load, Vin=230VAC
Io=Full Load
90
264 VAC
47
63 Hz
0
80
W
See rating chart V
See rating chart A
1.9 A
1.5 A
12 15
A
26 30
A
75 83 88
%
0.5 1
%
REG-o Load Regulation
Vin=230VAC
37
%
OVP Over Voltage Protection
112
132 %
OCP Over Current Protection
Ttr Transient Response
110
Io=Full Load to Half Load, Vin=100VAC
150 %
4
mS
Thold Hold-Up Time
Io=Full Load, Vin=100VAC
16
mS
Ts Start Up Time
Io=Full Load, Vin=100VAC
0.3 1 2
S
Vrn Ripple & Noise (Pe ak to Peak) Full Load, Vin=90VAC
Ilk Safety Ground Leakage Current Io=Full Load, Vin=240VAC
12
%
0.5 0.75 mA
Tc Temperature Coefficient
All output
-0.04
0.04 %/°c
Environmental :
Sym.
Parameter
Test Conditions
Toper
Tstg
Hr
Pd
Operating Temperature
Storage Temperature
Relative Humidity
Derate linearly from 100% load at 40°c to 50% load at 70°c
Safety Specifications:
Min. Typ. Max.
0
70
-40
85
5
95
Unit
°c
°c
%
Sym.
Parameter
Dielectric Withstanding Voltage
Vps
for Primary to secondary
Dielectric Withstanding Voltage
Vpg
for Primary to ground
Ri Isolation Resistance
CISPR EMI requirements for CISPR-22
FCC EMI requirements for FCC PART-15
Test Conditions
Primary to secondary
Primary to ground
Test Voltage = 500VDC
Vin=220VAC
Vin=110VAC
Min. Typ. Max. Unit
4242
VDC
2121
50
B
B
VDC
MW
CLASS
CLASS