English
Language : 

SPU60-101 Datasheet, PDF (1/2 Pages) Volgen Kaga Electronics Inc. – 60W Desk Top Switching Power Supplies For I.T.E.
SPU60 SERIES
60W Desk Top Switching Power Supplies For I.T.E.
Description:
The SPU60 series of AC/DC switching mode power supplies
provide 60 Watts of continuous output power. All supplies are
UL 94V-1 min compliant, include IEC-320-C14 input for
worldwide applications. All models meet FCC Part-15 class B
and CISPR-22 class B emission Limits and are designed to
comply with UL/c-UL(UL 1950), ITS/GS(EN 60950) and new
CE requirements. All units are 100% burned in and tested.
(Small Size)
Features:
Wide Input Voltage 90 to 264 VAC,47 to 63 Hz
IEC-320-C14 Input Inlet
Single output
Output Voltage Available From 3 VDC Thru 50 VDC
Optional Output Connector (See appendix)
Input Surge Current, Over Voltage and Over Load protection
Splash proof
Class I Insulation
Two Years Warranty
Safety Approvals :
C
US
Electrical Characteristics:
CB
S&E
Sym.
Parameter
Test Conditions
Min. Typ. Max. Unit
Vin Input Voltage
Fin Input Frequency
Wo Output Power Range
Vo Output Voltage Range
Io Output Current Range
Iil Input Current (Low Line)
Iih Input Current (High Line)
Operating Voltage
Vin=90 to 264VAC
Io=Full load, Vin=115VAC
Io=Full load, Vin=230VAC
90
264 VAC
47
63 Hz
0
60
W
See rating chart V
See rating chart A
1.6 A
1.0 A
Irl Low Line Inrush Current
Irh High Line Inrush Current
Eff Efficiency
REG-i Line Regulation
Io=Full load, 25°c, Cool start,
Vin=115VAC
12 15
A
Io=Full load, 25°c, Cool start,
Vin=230VAC
26 30
A
Io=Full Load, Vin=230VAC
70 83 88
%
Io=Full Load
0.5 1
%
REG-o Load Regulation
Vin=230VAC
37
%
OVP Over Voltage Protection
OCP Over Current Protection
112
132 %
110
150 %
Ttr Transient Response
Thold Hold-Up Time
Io=Full Load to Half Load, Vin=100VAC
Io=Full Load, Vin=110VAC
16
4
mS
mS
Ts Start Up Time
Io=Full Load, Vin=100VAC
Vrn Ripple & Noise (Pe ak to Peak) Full Load, Vin=90VAC
Ilk Safety Ground Leakage Curr ent Io=Full Load, Vin=240VAC
Tc Temperature Coefficient
All output
0.3 1
1
0.5
-0.04
2
2
0.75
0.04
S
%
mA
%/°c
Environmental :
Sym.
Parameter
Te s t Conditions
Toper Operating Temperature
Tstg Storage Temperature
Hr Relative Humidity
Pd Derate linearly from 100% load at 40 C to 50% load at 70 C
Min. Typ. Max. Unit
0
70
C
-40
85
C
5
95 %