English
Language : 

SPU45E-100 Datasheet, PDF (1/2 Pages) Volgen Kaga Electronics Inc. – 50W Desk Top Switching Power Supplies For I.T.E.
SPU45E SERIES
50W Desk Top Switching Power Supplies For I.T.E.
Description:
The SPU45E series of AC/DC switching mode power supplies
provide 50 Watts of continuous output power. All supplies are
UL 94V-0 compliant, include IEC-320-C14 input for worldwide
applications. All models meet FCC Part-15 class B and CISPR-
22 class B emission Limits and are designed to comply with UL,
C-UL, TUV and CE requirements. All units are 100% burned in
and tested.
Features:
Wide Input Voltage 90 to 264 VAC,47 to 63 Hz
IEC-320-C14 Input Inlet
Single to Triple Output
Output Voltage Available From 2VDC Thru 50VDC
Optional Output Connector (See appendix)
Input Surge Current, And Over Load protection
Splash proof
Class I Insulation
Two Years Warranty
Electrical Characteristics:
Safety Approvals :
Product Safety
CB
Sym.
Parameter
Test Conditions
Min. Typ. Max. Unit
Vin Input Voltage
90
264 VAC
Fin Input Frequency
47
63 Hz
Wo Output Power Range
Vin=90 to 264VAC
0
50
W
Vo Output Voltage Range
See rating chart V
Io Output Current Range
See rating chart A
Iil Input Current (Low Line)
Io=Full load, Vin=115VAC
1.35 A
Iih Input Current (High Line) Io=Full load, Vin=230 VAC
0.7 A
Irl Low Line Inrush Current
Io=Full load, 25°c, Cool start,
Vin=115VAC
12 15
A
Irh High Line Inrush Current
Io=Full load, 25°c, Cool start,
Vin=230VAC
26 30
A
Eff Efficiency
Io=Full Load, Vin=230VAC
70 75 80
%
REG-i Line Regulation
Io=Full Load
0.5 1
%
REG-o Load Regulation
Vin=230VAC
5 10
%
OVP Over Voltage Protection
(Optional)
OCP Over Current Protection
110
150 %
Ttr Transient Response
Io=Full Load to Half Load, Vin=100VAC
4
mS
Thold Hold-Up Time
Io=Full Load, Vin=100VAC
10
mS
Ts Start Up Time
Io=Full Load, Vin=100VAC
0.3 1 2
S
Vrn Ripple & Noise (Pea k to Peak) Full Load, Vin=90VAC
12
%
Ilk Safety Ground Leakage Current Io=Full Load, Vin=240VAC
0.5 0.75 mA
Tc Temperature Coefficient
All output
-0.04
0.04 %/°c
Environmental :
Sym.
Parameter
Test Conditions
Toper
Tstg
Hr
Pd
Operating Temperature
Storage Temperature
Relative Humidity
Derate linearly from 100% load at 40°c to 50% load at 70°c
Safety Specifications:
Min. Typ. Max.
0
70
-40
85
5
95
Unit
°c
°c
%
Sym.
Parameter
Dielectric Withstanding Voltage
Vps
for Primary to secondary
Dielectric Withstanding Voltage
Vpg
for Primary to ground
Ri Isolation Resistance
CISPR EMI requirements for CISPR-22
FCC EMI requirements for FCC PART-15
Test Conditions
Primary to secondary
Primary to ground
Test Voltage = 500VDC
Vin=220VAC
Vin=110VAC
Min. Typ. Max. Unit
4242
VDC
2121
50
B
B
VDC
MW
CLASS
CLASS