English
Language : 

SPU12B-101 Datasheet, PDF (1/2 Pages) Volgen Kaga Electronics Inc. – 15W Wall Mount Switching Power Supplies For I.T.E.
SPU12B SERIES
15W Wall Mount Switching Power Supplies For I.T.E.
Description:
The SPU12B series of AC/DC switching mode power
supplies provide 15 Watts of continuous output power. All
supplies are UL 94V-1 min compliant, include a 3 prong
plug-in mains connector for certain applications. All models
meet CISPR-22 class B emission Limits and are designed to
comply with new CE requirements. All units are 100%
burned in and tested.
Features:
Wide Input Voltage 90 to 264 VAC,47 to 63 Hz
3 Prong Plug-In Mains Connector
Output Voltage Available From 3VDC Thru 50VDC
Optional Output Connector (See appendix)
Single Output
Class II Insulation (Double Insulation)
Two years warranty
Safety Approvals:
Electrical Characteristics:
CB
Sym.
Parameter
Test Conditions
Min. Typ. Max. Unit
Vin Input Voltage
Operating Voltage
90
264 VAC
Fin Input Frequency
47
63 Hz
Wo Output Power Range
Vin=90 to 264VAC
0
15 W
Vo Output Voltage Range
See rating chart V
Io Output Current Range
See rating chart A
Iil Input Current (Low Line) Io=Full load, Vin=115VAC
0.4 A
Iih Input Current (High Line) Io=Full load, Vin=230VAC
0.3 A
Irl Low Line Inrush Current
Io=Full load, 25°c, Cool start,
Vin=115VAC
12 15 A
Irh High Line Inrush Current
Io=Full load, 25°c, Cool start,
Vin=230VAC
26 30 A
Eff Efficiency
Io=Full Load, Vin=230VAC
60 70 78 %
REG-i Line Regulation
Io=Full Load
0.5 1
%
REG-o Load Regulation
Vin=230VAC
37
%
OVP Over Voltage Protection
Nil
%
OCP Over Current Protection Nil But,Output protected to short circuit conditions %
Ttr Transient Response
Io=Full Load to Half Load, Vin=100VAC
4 mS
Thold Hold-Up Time
Io=Full Load, Vin=110VAC
5
mS
Ts Start Up Time
Io=Full Load, Vin=100VAC
0.3 1 2
S
Vrn Ripple & Noise(Peak to Peak) Full Load, Vin=90VAC
12
%
Ilk Safety Ground Leakage Current Io=Full Load, Vin=240VAC
0.5 0.75 mA
Tc Temperature Coefficient
All output
-0.04
0.04 %/°c
Environmental :
Sym.
Parameter
Te s t Conditions
Toper Operating Temperature
Tstg Storage Temperature
Hr Relative Humidity
No-Condensing
Pd Derate linearly from 100% load at 40 C to 50% load at 70 C
Min. Typ. Max. Unit
0
70
C
-40
85
C
5
95 %