English
Language : 

SBU60 Datasheet, PDF (1/2 Pages) DB Lectro Inc – 63W Open Frame Switching Power Supplies For I.T.E.
SBU60 SERIES
63W Open Frame Switching Power Supplies For I.T.E.
Description:
The SBU60 series of compact, open frame constructed, AC/DC
switching mode power supplies provide 63 Watts of continuous output
power . They are ideally suited for use in CRT terminals, disc drive
systems, microprocess or based systems, por table equipments and
many other applications, all models are designed to meet the safety
requirements of UL1950/EN60950 requirements. All units are 100%
burned in and tested.
Features:
+ Wide Input Voltage 90 to 264 VAC,47 to 63 Hz
+ Internal EMI filter
+ Single to Quad Output
+ Input connector mates with Molex housing 09-50-3051 and
Molex 2878 series crimp terminal
+ Output connector mates with Molex housing 09-50-3061
(or 09-50-3081) and Molex 2878 series crimp terminal
+ Output Voltage Available From 3 VDC Thru 50 VDC
+ Input Surge Current, Over Voltage and Over Load protection
+ One Year Warranty
Electrical Characteristics:
SSaaffeettyy AApppprroovvaallss ::
C
US
Bauart
gepruft
CB
Sym.
Parameter
Test Conditions
Min. Typ. Max. Unit
Vin Input Voltage
90
264 VAC
Fin Input Frequency
47
63 Hz
Wo Output Power Range
Vin=90 to 264VAC
0
63
W
Vo Output Voltage Range
See rating chart V
Io Output Current Range
See rating chart A
Iil Input Current (Low Line)
Io=Full load, Vin=115VAC
1.6 A
Iih Input Current (High Line) Io=Full load, Vin=230 VAC
1.0 A
Irl Low Line Inrush Current
Io=Full load, 25°c, Cool start,
Vin=115VAC
12 15
A
Irh High Line Inrush Current
Io=Full load, 25°c, Cool start,
Vin=230VAC
26 30
A
Eff Efficiency
Io=Full Load, Vin=230VAC
70 80 88
%
REG-i Line Regulation
Io=Full Load
0.5 1
%
REG-o Load Regulation
Vin=230VAC
36
%
OVP Over Voltage Protection
112
132 %
OCP Over Current Protection
110
150 %
Ttr Transient Response
Io=Full Load to Half Load, Vin=100VAC
4
mS
Thold Hold-Up Time
Io=Full Load, Vin=100VAC
18 20
mS
Ts Start Up Time
Io=Full Load, Vin=100VAC
0.3 1 2
S
Vrn Ripple & Noise (Pe ak to Peak) Full Load, Vin=90VAC
12
%
Ilk Safety Ground Leakage Current Io=Full Load, Vin=240VAC
0.4 0.45 mA
Tc Temperature Coefficient
Final value within 500u s after 25%
1
step
4 %/°c
Environmental :
Sym.
Parameter
Test Conditions
Toper
Tstg
Hr
Pd
Operating Temperature
Storage Temperature
Relative Humidity
Derate linearly from 100% load at 40°c to 50% load at 70°c
Safety Specifications:
Min. Typ. Max.
0
70
-40
85
5
95
Unit
°c
°c
%
Sym.
Parameter
Dielectric Withstanding Voltage
Vps
for Primary to secondary
Dielectric Withstanding Voltage
Vpg
for Primary to ground
Ri Isolation Resistance
CISPR EMI requirements for CISPR-22
FCC EMI requirements for FCC PART-15
Test Conditions
Primary to secondary
Primary to ground
Test Voltage = 500VDC
Vin=220VAC
Vin=110VAC
Min. Typ. Max. Unit
4242
VDC
2121
50
B
B
VDC
MW
CLASS
CLASS