English
Language : 

TNPW08053K32BEEN Datasheet, PDF (8/11 Pages) Vishay Siliconix – High Stability Thin Film Flat Chip Resistors
www.vishay.com
FUNCTIONAL PERFORMANCE
10 000 V
TNPW e3
Vishay
1000 V TNPW1206 e3
100 V
TNPW0805 e3
TNPW0603 e3
Conditions:
Pi ≤ Pi, max.
10 V
10 µs 100 µs
1 ms
10 ms
Maximum Pulse Voltage Ui, max.
100 ms 1 s
10 s
Pulse Duration ti
TEST AND REQUIREMENTS
All tests are carried out in accordance with the following
specifications:
EN 60115-1, generic specification (incluces tests)
EN 140400, sectional specification (includes schedule for
qualification approval)
EN 140401-801, detail specification (includes schedule for
conformance inspection)
The testing also covers most of the requirements specified
by EIA/ECA-703 and JIS-C-5201-1. The tests are carried out
under standard atmospheric conditions in accordance with
IEC 60068-1, 5.3. A climate category is applied, defined by
the lower category temperature (LCT), the upper category
temperature (UCT), and the number of days of the damp
heat, steady-state test (56).
Unless otherwise specified the following values apply:
Temperature: 15 °C to 35 °C
Relative humidity: 45 % to 75 %
Air pressure: 86 kPa to 106 kPa (860 mbar to 1060 mbar).
The components are mounted for testing on boards in
accordance with EN 60115-1, 4.31 unless otherwise
specified. The parameters stated in the Test Procedures and
Requirements table are based on the required tests and
permitted limits of EN 140401-801.
TEST PROCEDURES AND REQUIREMENTS
EN 60115-1  IEC 60068-2
CLAUSE TEST METHOD
TEST
PROCEDURE
REQUIREMENTS
PERMISSIBLE CHANGE (R)
Stability for product types:
TNPW0402 e3
TNPW0603 e3
TNPW0805 e3
TNPW1206 e3
4.5
4.8.4.2
4.25.1
TNPW1210 e3
-
Resistance
-
± 1 %; ± 0.5 %; ± 0.1 %
-
Temperature
coefficient
At (20/- 55/20) °C and (20/125/20) °C ± 50 ppm/K; ± 25 ppm/K; ± 15 ppm/K; ± 10 ppm/K
U = P70 x R or
U = Umax.;
whichever is the less severe;
-
Endurance at
70 °C
1.5 h on; 0.5 h off;
70 °C; 1000 h
± (0.05 % R + 0.01 )
70 °C; 8000 h
± (0.1 % R + 0.02 )
4.25.3
4.24
-
78 (Cab)
Endurance at
upper category
temperature
Damp heat,
steady state
125 °C; 1000 h
155 °C; 1000 h
(40 ± 2) °C; 56 days;
(93 ± 3) % RH
± (0.05 % R + 0.01 )
± (0.1 % R + 0.02 )
± (0.1 % R + 0.01 )
Revision: 05-Feb-14
8
Document Number: 28758
For technical questions, contact: thinfilmchip@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000